On the Optimum Sampling Time for the Measurement of Pollutants in Ambient Air

المؤلفون المشاركون

Hood, Daniel
Brown, Richard J. C.
Brown, Andrew S.

المصدر

Journal of Automated Methods and Management in Chemistry

العدد

المجلد 2008، العدد 2008 (31 ديسمبر/كانون الأول 2008)، ص ص. 1-6، 6ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2008-03-13

دولة النشر

مصر

عدد الصفحات

6

التخصصات الرئيسية

الكيمياء

الملخص EN

No measurement result of any kind is complete without an associated statement of uncertainty.

In general, the aim is to minimise this measurement uncertainty to the extent that the measurement made is fit for purpose, or the uncertainty meets an acceptable level such as a ‘‘data quality objective’’.

This paper demonstrates how the sampling time used to measure a pollutant in ambient air over a given time period, particularly with automatic instruments, can affect the uncertainty of the measurement result.

It is shown that the uncertainty of the overall result depends critically on how the precision characteristics of the measuring instrumentation vary with analyte abundance.

An example of the determination of these characteristics for mercury vapour measurement and the conclusions that may be drawn about optimum sampling times to minimise uncertainty are presented.

For situations where uncertainty is minimised by the use of long sampling periods, the implications of this strategy on the ‘‘information richness’’ of the data and on the detection of short-term episodes, as well as peak concentrations, are discussed.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Brown, Richard J. C.& Hood, Daniel& Brown, Andrew S.. 2008. On the Optimum Sampling Time for the Measurement of Pollutants in Ambient Air. Journal of Automated Methods and Management in Chemistry،Vol. 2008, no. 2008, pp.1-6.
https://search.emarefa.net/detail/BIM-500226

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Brown, Richard J. C.…[et al.]. On the Optimum Sampling Time for the Measurement of Pollutants in Ambient Air. Journal of Automated Methods and Management in Chemistry No. 2008 (2008), pp.1-6.
https://search.emarefa.net/detail/BIM-500226

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Brown, Richard J. C.& Hood, Daniel& Brown, Andrew S.. On the Optimum Sampling Time for the Measurement of Pollutants in Ambient Air. Journal of Automated Methods and Management in Chemistry. 2008. Vol. 2008, no. 2008, pp.1-6.
https://search.emarefa.net/detail/BIM-500226

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-500226