Modelling of Heat Transfer Phenomena for Vertical and Horizontal Configurations of In-Pool Condensers and Comparison with Experimental Findings
المؤلفون المشاركون
المصدر
Science and Technology of Nuclear Installations
العدد
المجلد 2010، العدد 2010 (31 ديسمبر/كانون الأول 2010)، ص ص. 1-16، 16ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2010-03-25
دولة النشر
مصر
عدد الصفحات
16
التخصصات الرئيسية
العلوم الهندسية و تكنولوجيا المعلومات
الملخص EN
Decay Heat Removal (DHR) is a fundamental safety function which is often accomplished in the advanced LWRs relying on natural phenomena.
A typical passive DHR system is the two-phase flow, natural circulation, closed loop system, where heat is removed by means of a steam generator or heat exchanger, a condenser, and a pool.
Different condenser tube arrangements have been developed for applications to the next generation NPPs.
The two most used configurations, namely, horizontal and vertical tube condensers, are thoroughly investigated in this paper.
Several thermal-hydraulic features were explored, being the analysis mainly devoted to the description of the best-estimate correlations and models for heat transfer coefficient prediction.
In spite of a more critical behaviour concerning thermal expansion issues, vertical tube condensers offer remarkably better thermal-hydraulic performances.
An experimental validation of the vertical tube correlations is provided by PERSEO facility (SIET labs, Piacenza), showing a fairly good agreement.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Papini, Davide& Cammi, Antonio. 2010. Modelling of Heat Transfer Phenomena for Vertical and Horizontal Configurations of In-Pool Condensers and Comparison with Experimental Findings. Science and Technology of Nuclear Installations،Vol. 2010, no. 2010, pp.1-16.
https://search.emarefa.net/detail/BIM-500336
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Papini, Davide& Cammi, Antonio. Modelling of Heat Transfer Phenomena for Vertical and Horizontal Configurations of In-Pool Condensers and Comparison with Experimental Findings. Science and Technology of Nuclear Installations No. 2010 (2010), pp.1-16.
https://search.emarefa.net/detail/BIM-500336
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Papini, Davide& Cammi, Antonio. Modelling of Heat Transfer Phenomena for Vertical and Horizontal Configurations of In-Pool Condensers and Comparison with Experimental Findings. Science and Technology of Nuclear Installations. 2010. Vol. 2010, no. 2010, pp.1-16.
https://search.emarefa.net/detail/BIM-500336
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-500336
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر