![](/images/graphics-bg.png)
An In Vitro Evaluation of Leakage of Two Etch and Rinse and Two Self-Etch Adhesives after Thermocycling
المؤلفون المشاركون
Bolette, Amandine
Seidel, Laurence
Guéders, Audrey
Geerts, Sabine O.
المصدر
International Journal of Dentistry
العدد
المجلد 2012، العدد 2012 (31 ديسمبر/كانون الأول 2012)، ص ص. 1-7، 7ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2012-05-22
دولة النشر
مصر
عدد الصفحات
7
التخصصات الرئيسية
الملخص EN
Our experiment evaluated the microleakage in resin composite restorations bonded to dental tissues with different adhesive systems.
40 class V cavities were prepared on the facial and lingual surfaces of each tooth with coronal margins in enamel and apical margins in cementum (root dentin).
The teeth were restored with Z100 resin composite bonded with different adhesive systems: Scotchbond Multipurpose (SBMP), a 3-step Etch and Rinse adhesive, Adper Scotchbond 1 XT (SB1), a 2-step Etch and Rinse adhesive, AdheSE One (ADSE-1), a 1-step Self-Etch adhesive, and AdheSE (ADSE), a 2-step Self-Etch adhesive.
Teeth were thermocycled and immersed in 50% silver nitrate solution.
When both interfaces were considered, SBMP has exhibited significantly less microleakage than other adhesive systems (resp., for SB1, ADSE-1 and ADSE, P=0.0007, P<0.0001 and P<0.0001).
When enamel and dentin interfaces were evaluated separately, (1) for the Self-Etch adhesives, microleakage was found greater at enamel than at dentin interfaces (for ADSE, P=0.024 and for ADSE-1, P<0.0001); (2) for the Etch and Rinse adhesive systems, there was no significant difference between enamel and dentin interfaces; (3) SBMP was found significantly better than other adhesives both at enamel and dentin interfaces.
In our experiment Etch and Rinse adhesives remain better than Self-Etch adhesives at enamel interface.
In addition, there was no statistical difference between 1-step (ADSE-1) and 2-step (ADSE) Self-Etch adhesives.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Geerts, Sabine O.& Bolette, Amandine& Seidel, Laurence& Guéders, Audrey. 2012. An In Vitro Evaluation of Leakage of Two Etch and Rinse and Two Self-Etch Adhesives after Thermocycling. International Journal of Dentistry،Vol. 2012, no. 2012, pp.1-7.
https://search.emarefa.net/detail/BIM-503450
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Geerts, Sabine O.…[et al.]. An In Vitro Evaluation of Leakage of Two Etch and Rinse and Two Self-Etch Adhesives after Thermocycling. International Journal of Dentistry No. 2012 (2012), pp.1-7.
https://search.emarefa.net/detail/BIM-503450
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Geerts, Sabine O.& Bolette, Amandine& Seidel, Laurence& Guéders, Audrey. An In Vitro Evaluation of Leakage of Two Etch and Rinse and Two Self-Etch Adhesives after Thermocycling. International Journal of Dentistry. 2012. Vol. 2012, no. 2012, pp.1-7.
https://search.emarefa.net/detail/BIM-503450
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-503450
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)