CFD Analysis of Passive Autocatalytic Recombiner

المؤلفون المشاركون

Sharma, Pavan K.
Vaze, K. K.
Singh, R. K.
Gera, B.

المصدر

Science and Technology of Nuclear Installations

العدد

المجلد 2011، العدد 2011 (31 ديسمبر/كانون الأول 2011)، ص ص. 1-9، 9ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2011-09-29

دولة النشر

مصر

عدد الصفحات

9

التخصصات الرئيسية

العلوم الهندسية و تكنولوجيا المعلومات

الملخص EN

In water-cooled nuclear power reactors, significant quantities of hydrogen could be produced following a postulated loss-of-coolant accident (LOCA) along with nonavailability of emergency core cooling system (ECCS).

Passive autocatalytic recombiners (PAR) are implemented in the containment of water-cooled power reactors to mitigate the risk of hydrogen combustion.

In the presence of hydrogen with available oxygen, a catalytic reaction occurs spontaneously at the catalyst surfaces below conventional ignition concentration limits and temperature and even in presence of steam.

Heat of reaction produces natural convection flow through the enclosure and promotes mixing in the containment.

For the assessment of the PAR performance in terms of maximum temperature of catalyst surface and outlet hydrogen concentration an in-house 3D CFD model has been developed.

The code has been used to study the mechanism of catalytic recombination and has been tested for two literature-quoted experiments.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Gera, B.& Sharma, Pavan K.& Singh, R. K.& Vaze, K. K.. 2011. CFD Analysis of Passive Autocatalytic Recombiner. Science and Technology of Nuclear Installations،Vol. 2011, no. 2011, pp.1-9.
https://search.emarefa.net/detail/BIM-504317

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Gera, B.…[et al.]. CFD Analysis of Passive Autocatalytic Recombiner. Science and Technology of Nuclear Installations No. 2011 (2011), pp.1-9.
https://search.emarefa.net/detail/BIM-504317

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Gera, B.& Sharma, Pavan K.& Singh, R. K.& Vaze, K. K.. CFD Analysis of Passive Autocatalytic Recombiner. Science and Technology of Nuclear Installations. 2011. Vol. 2011, no. 2011, pp.1-9.
https://search.emarefa.net/detail/BIM-504317

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل