Safety and Efficacy of the Prostar XL Vascular Closing Device for Percutaneous Closure of Large Arterial Access Sites
المؤلفون المشاركون
Steger, Volker
Brechtel, Klaus
Thomas, Christoph
Ketelsen, Dominik
Heller, Stefan
Heuschmid, Martin
Claussen, Claus D.
المصدر
Radiology Research and Practice
العدد
المجلد 2013، العدد 2013 (31 ديسمبر/كانون الأول 2013)، ص ص. 1-6، 6ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2013-01-14
دولة النشر
مصر
عدد الصفحات
6
التخصصات الرئيسية
الملخص EN
Purpose.
The purpose of this study is to retrospectively evaluate the efficacy and safety of the Prostar XL device for percutaneous large access site closure in an unselected patient and operator collective.
Materials and Methods.
All patients (n=50) who had received percutaneous vascular closing with the Prostar XL device in our institution with follow-up data of at least 6 months were retrospectively included.
Primary (freedom from surgical conversion) and continued (freedom from groin surgery in further course) technical success and major (deviations from expected outcome requiring surgery) and minor (other deviations from expected outcome) complications were assessed.
Success and complications rates were correlated with delivery system size (Mann-Whitney Rank Sum Tests) and operator experience (paired samples t-test).
Results.
Rates of primary and continued technical success as well as major and minor complications were 93.6%, 89.7%, 10.3%, and 10.3% (groin based) and 90.0%, 84.0%, 16.0%, and 16.0% (patient based), respectively.
No correlation of success and complications rate was found with delivery system sizes and operator experience.
Conclusions.
Application of the Prostar XL device for percutaneous closure of large arterial access sites is safe with a relatively high rate of technical success and low rate of major complications.
Sizes of the delivery systems and the experience of the operator did not influence the results.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Thomas, Christoph& Steger, Volker& Heller, Stefan& Heuschmid, Martin& Ketelsen, Dominik& Claussen, Claus D.…[et al.]. 2013. Safety and Efficacy of the Prostar XL Vascular Closing Device for Percutaneous Closure of Large Arterial Access Sites. Radiology Research and Practice،Vol. 2013, no. 2013, pp.1-6.
https://search.emarefa.net/detail/BIM-505396
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Thomas, Christoph…[et al.]. Safety and Efficacy of the Prostar XL Vascular Closing Device for Percutaneous Closure of Large Arterial Access Sites. Radiology Research and Practice No. 2013 (2013), pp.1-6.
https://search.emarefa.net/detail/BIM-505396
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Thomas, Christoph& Steger, Volker& Heller, Stefan& Heuschmid, Martin& Ketelsen, Dominik& Claussen, Claus D.…[et al.]. Safety and Efficacy of the Prostar XL Vascular Closing Device for Percutaneous Closure of Large Arterial Access Sites. Radiology Research and Practice. 2013. Vol. 2013, no. 2013, pp.1-6.
https://search.emarefa.net/detail/BIM-505396
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-505396
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر