Laryngeal Radiation Fibrosis : A Case of Failed Awake Flexible Fibreoptic Intubation

المؤلفون المشاركون

Zijp, Lambert
Huitink, Johannes M.

المصدر

Case Reports in Anesthesiology

العدد

المجلد 2011، العدد 2011 (31 ديسمبر/كانون الأول 2011)، ص ص. 1-4، 4ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2011-12-19

دولة النشر

مصر

عدد الصفحات

4

التخصصات الرئيسية

الطب البشري

الملخص EN

Awake fibreoptic intubation is accepted as the gold standard for intubation of patients with an anticipated difficult airway.

Radiation fibrosis may cause difficulties during the intubation procedure.

We present an unusual severe case of radiation induced changes to the larynx, with limited clinical symptoms, that caused failure of the fibreoptic intubation technique.

A review of the known literature on radiation fibrosis and airway management is presented.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Huitink, Johannes M.& Zijp, Lambert. 2011. Laryngeal Radiation Fibrosis : A Case of Failed Awake Flexible Fibreoptic Intubation. Case Reports in Anesthesiology،Vol. 2011, no. 2011, pp.1-4.
https://search.emarefa.net/detail/BIM-505596

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Huitink, Johannes M.& Zijp, Lambert. Laryngeal Radiation Fibrosis : A Case of Failed Awake Flexible Fibreoptic Intubation. Case Reports in Anesthesiology No. 2011 (2011), pp.1-4.
https://search.emarefa.net/detail/BIM-505596

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Huitink, Johannes M.& Zijp, Lambert. Laryngeal Radiation Fibrosis : A Case of Failed Awake Flexible Fibreoptic Intubation. Case Reports in Anesthesiology. 2011. Vol. 2011, no. 2011, pp.1-4.
https://search.emarefa.net/detail/BIM-505596

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل