The Analysis of the Artifacts due to the Simultaneous Use of Two Ultrasound Probes with DifferentSimilar Operating Frequencies

المؤلفون المشاركون

Hashmani, Manzoor
Hasan, Musarrat
Chowdhry, B. S.
Amir, Samreen

المصدر

Computational and Mathematical Methods in Medicine

العدد

المجلد 2013، العدد 2013 (31 ديسمبر/كانون الأول 2013)، ص ص. 1-5، 5ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2013-03-31

دولة النشر

مصر

عدد الصفحات

5

التخصصات الرئيسية

الطب البشري

الملخص EN

The ultrasound imaging has the potential to become a dominant technique for noninvasive therapies and least invasive surgeries.

Few cases may require using multiple probes of different units with different modes of ultrasound on the same patient.

It generates imaging artifacts, which makes it complicated to gather information from the acquired image.

This study was to identify and analyse the artifacts which are produced by simultaneous use of two probes with different/same operating frequencies.

Six imaging studies were performed.

First of all, the imaging artifacts of the 3.5 MHz and 6 MHz center frequencies with similar (longitudinal) positions of the probes.

Secondly, with similar operating frequencies the 6 MHz probe changed from longitudinal to transverse placement to analyse the resulting artifacts.

The third study was done with transverse placement of 3.5 MHz probe.

The rest of the three cases were just the repetition with common pulse frequencies.

Such artifacts in 3D ultrasound images are more obscure than the other artifacts associated and reported.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Amir, Samreen& Chowdhry, B. S.& Hashmani, Manzoor& Hasan, Musarrat. 2013. The Analysis of the Artifacts due to the Simultaneous Use of Two Ultrasound Probes with DifferentSimilar Operating Frequencies. Computational and Mathematical Methods in Medicine،Vol. 2013, no. 2013, pp.1-5.
https://search.emarefa.net/detail/BIM-505691

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Amir, Samreen…[et al.]. The Analysis of the Artifacts due to the Simultaneous Use of Two Ultrasound Probes with DifferentSimilar Operating Frequencies. Computational and Mathematical Methods in Medicine No. 2013 (2013), pp.1-5.
https://search.emarefa.net/detail/BIM-505691

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Amir, Samreen& Chowdhry, B. S.& Hashmani, Manzoor& Hasan, Musarrat. The Analysis of the Artifacts due to the Simultaneous Use of Two Ultrasound Probes with DifferentSimilar Operating Frequencies. Computational and Mathematical Methods in Medicine. 2013. Vol. 2013, no. 2013, pp.1-5.
https://search.emarefa.net/detail/BIM-505691

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-505691