One-Haptic Fixation of Posterior Chamber Intraocular Lenses without Scleral Flaps

المؤلفون المشاركون

Ghanem, Asaad Ghanem
Moawad, Ashraf I.

المصدر

Journal of Ophthalmology

العدد

المجلد 2012، العدد 2012 (31 ديسمبر/كانون الأول 2012)، ص ص. 1-5، 5ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2012-08-05

دولة النشر

مصر

عدد الصفحات

5

التخصصات الرئيسية

الطب البشري

الملخص EN

Purpose.

To assess visual results and complications of a modified technique of posterior chamber intraocular lenses (PC IOLs) in aphakic eyes without scleral flaps.

Methods.

Modified one-haptic scleral fixation was performed in one eye each of 25 patients with aphakia and insufficient capsule support.

Follow-up period was six months.

Outcome measures included best-corrected visual acuity, intraocular pressure (IOP), and postoperative complications.

Results.

The study included 15 males and 10 females.

The preoperative best-corrected visual acuity (BCVA) ranged from 5/60 to 6/9.

The operation time ranged from 25 to 45 minutes (mean 35.25 ± 5.34 min).

Anterior vitrectomy was performed in 12 cases (48%).

There was no major IOL decentration.

The final BCVA ranged from 6/36 to 6/9.

Seven cases (28%) showed postoperative glaucoma, five cases (20%) had temporary hypotony, and hyphema in 2 eyes (8%).

No cases of suture erosion, postoperative endophthalmitis, retinal detachment, or IOL dislocation were detected.

Conclusion.

This technique of one-haptic scleral fixation of posterior chamber IOLs is a good choice in presence of insufficient capsule support.

It reduces the operation time, achieves the IOL stability, and minimizes postoperative suture-related complications.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Moawad, Ashraf I.& Ghanem, Asaad Ghanem. 2012. One-Haptic Fixation of Posterior Chamber Intraocular Lenses without Scleral Flaps. Journal of Ophthalmology،Vol. 2012, no. 2012, pp.1-5.
https://search.emarefa.net/detail/BIM-505877

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Moawad, Ashraf I.& Ghanem, Asaad Ghanem. One-Haptic Fixation of Posterior Chamber Intraocular Lenses without Scleral Flaps. Journal of Ophthalmology No. 2012 (2012), pp.1-5.
https://search.emarefa.net/detail/BIM-505877

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Moawad, Ashraf I.& Ghanem, Asaad Ghanem. One-Haptic Fixation of Posterior Chamber Intraocular Lenses without Scleral Flaps. Journal of Ophthalmology. 2012. Vol. 2012, no. 2012, pp.1-5.
https://search.emarefa.net/detail/BIM-505877

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل