الملخص EN

Glaucoma is a group of heterogeneous disorders involving progressive optic neuropathy that can culminate into visual impairment and irreversible blindness.

Effective therapeutic interventions must address underlying vulnerability of retinal ganglion cells (RGCs) to degeneration in conjunction with correcting other associated risk factors (such as elevated intraocular pressure).

However, realization of therapeutic outcomes is heavily dependent on suitable delivery system that can overcome myriads of anatomical and physiological barriers to intraocular drug delivery.

Development of clinically viable sustained release systems in glaucoma is a widely recognized unmet need.

In this regard, implantable delivery systems may relieve the burden of chronic drug administration while potentially ensuring high intraocular drug bioavailability.

Presently there are no FDA-approved implantable drug delivery devices for glaucoma even though there are several ongoing clinical studies.

The paper critically assessed the prospects of polymeric implantable delivery systems in glaucoma while identifying factors that can dictate (a) patient tolerability and acceptance, (b) drug stability and drug release profiles, (c) therapeutic efficacy, and (d) toxicity and biocompatibility.

The information gathered could be useful in future research and development efforts on implantable delivery systems in glaucoma.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Manickavasagam, Dharani& Oyewumi, Moses O.. 2013. Critical Assessment of Implantable Drug Delivery Devices in Glaucoma Management. Journal of Drug Delivery،Vol. 2013, no. 2013, pp.1-12.
https://search.emarefa.net/detail/BIM-506157

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Manickavasagam, Dharani& Oyewumi, Moses O.. Critical Assessment of Implantable Drug Delivery Devices in Glaucoma Management. Journal of Drug Delivery No. 2013 (2013), pp.1-12.
https://search.emarefa.net/detail/BIM-506157

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Manickavasagam, Dharani& Oyewumi, Moses O.. Critical Assessment of Implantable Drug Delivery Devices in Glaucoma Management. Journal of Drug Delivery. 2013. Vol. 2013, no. 2013, pp.1-12.
https://search.emarefa.net/detail/BIM-506157

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-506157