![](/images/graphics-bg.png)
A Clinical Study of the Pulse Wave Characteristics at the Three Pulse Diagnosis Positions of Chon, Gwan and Cheok
المؤلفون المشاركون
Ryu, Hyun H.
Lee, Hae Jung
Lee, Jeon
Kim, Jaeuk U.
Kim, Jong Yeol
Lee, Yu J.
Jeon, Young Ju
المصدر
Evidence-Based Complementary and Alternative Medicine
العدد
المجلد 2011، العدد 2011 (31 ديسمبر/كانون الأول 2011)، ص ص. 1-9، 9ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2011-05-02
دولة النشر
مصر
عدد الصفحات
9
التخصصات الرئيسية
الملخص EN
In this work, we analyze the baseline, signal strength, aortic augmentation index (AIx), radial AIx, time to reflection and P_T2 at Chon, Gwan, and Cheok, which are the three pulse diagnosis positions in Oriental medicine.
For the pulse measurement, we used the SphygmoCor apparatus, which has been widely used for the evaluation of the arterial stiffness at the aorta.
By two-way repeated measures analysis of variance, we tested two independent measurements for repeatability and investigated their mean differences among Chon, Gwan and Cheok.
To characterize further the parameters that were shown to be different between each palpation position, we carried out Duncan's test for the multiple comparisons.
The baseline and signal strength were statistically different (P<.05) among Chon, Gwan and Cheok, respectively, which supports the major hypothesis of Oriental medicine that all of the three palpation positions contain different clinical information.
On the other hand, aortic AIx and time to reflection were found to be statistically different between Chon and the others, and radial AIx and P_T2 did not show any difference between pulse positions.
In the clinical sense, however, the aortic AIx at each palpation position was found to fall within the 90% confidence interval of normal arterial compliance.
The results of the multiple comparisons indicate that the parameters of arterial stiffness were independent of the palpation positions.
This work is the first attempt to characterize quantitatively the pulse signals at Chon, Gwan and Cheok with some relevant parameters extracted from the SphygmoCor apparatus.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Jeon, Young Ju& Kim, Jaeuk U.& Lee, Hae Jung& Lee, Jeon& Ryu, Hyun H.& Lee, Yu J.…[et al.]. 2011. A Clinical Study of the Pulse Wave Characteristics at the Three Pulse Diagnosis Positions of Chon, Gwan and Cheok. Evidence-Based Complementary and Alternative Medicine،Vol. 2011, no. 2011, pp.1-9.
https://search.emarefa.net/detail/BIM-506791
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Jeon, Young Ju…[et al.]. A Clinical Study of the Pulse Wave Characteristics at the Three Pulse Diagnosis Positions of Chon, Gwan and Cheok. Evidence-Based Complementary and Alternative Medicine No. 2011 (2011), pp.1-9.
https://search.emarefa.net/detail/BIM-506791
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Jeon, Young Ju& Kim, Jaeuk U.& Lee, Hae Jung& Lee, Jeon& Ryu, Hyun H.& Lee, Yu J.…[et al.]. A Clinical Study of the Pulse Wave Characteristics at the Three Pulse Diagnosis Positions of Chon, Gwan and Cheok. Evidence-Based Complementary and Alternative Medicine. 2011. Vol. 2011, no. 2011, pp.1-9.
https://search.emarefa.net/detail/BIM-506791
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-506791
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)