![](/images/graphics-bg.png)
The Effects of QuikClot Combat Gauze, Fluid Resuscitation, and Movement on Hemorrhage Control in a Porcine Model
المؤلفون المشاركون
Taylor, Alexis
Johnson, Don
Gegel, Brian
Gasko, John
Cromwell, Carrie
Burgert, James
Jaskowska, Monika
Steward, Rachel
المصدر
العدد
المجلد 2012، العدد 2012 (31 ديسمبر/كانون الأول 2012)، ص ص. 1-6، 6ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2012-11-29
دولة النشر
مصر
عدد الصفحات
6
التخصصات الرئيسية
الملخص EN
The purpose of this study was to compare the effectiveness of QuikClot Combat Gauze (QCG) compared to a control group on hemorrhage control; the amount of crystalloid volume infusion on rebleeding; the effect of movement on hemorrhage.
This was a prospective, experimental design.
Swine were randomly assigned to either the QCG (n=11) or the control group (n=11).
Investigators transected the femoral artery and vein in each swine.
After one minute of uncontrolled hemorrhage, the hemostatic agent, QCG, was placed into the wound followed by standard wound packing.
The control group underwent the same procedures but without a hemostatic agent.
After five minutes of direct pressure, a standard pressure dressing was applied.
After 30 minutes, dressings were removed, and the wound was observed for rebleeding for 5 minutes.
If hemostasis occurred, 5 liters of crystalloid was given over 5 minutes, and the wound was observed for rebleeding for 5 additional minutes.
If no bleeding occurred, the extremity on the side of the injury was moved.
There were significant differences in the amount of hemorrhage (P=0.018), the amount of fluid administration (P<0.001), and the number of movements (P=0.001) between the QCG and control.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Johnson, Don& Gegel, Brian& Burgert, James& Gasko, John& Cromwell, Carrie& Jaskowska, Monika…[et al.]. 2012. The Effects of QuikClot Combat Gauze, Fluid Resuscitation, and Movement on Hemorrhage Control in a Porcine Model. ISRN Emergency Medicine،Vol. 2012, no. 2012, pp.1-6.
https://search.emarefa.net/detail/BIM-508807
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Johnson, Don…[et al.]. The Effects of QuikClot Combat Gauze, Fluid Resuscitation, and Movement on Hemorrhage Control in a Porcine Model. ISRN Emergency Medicine No. 2012 (2012), pp.1-6.
https://search.emarefa.net/detail/BIM-508807
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Johnson, Don& Gegel, Brian& Burgert, James& Gasko, John& Cromwell, Carrie& Jaskowska, Monika…[et al.]. The Effects of QuikClot Combat Gauze, Fluid Resuscitation, and Movement on Hemorrhage Control in a Porcine Model. ISRN Emergency Medicine. 2012. Vol. 2012, no. 2012, pp.1-6.
https://search.emarefa.net/detail/BIM-508807
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-508807
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)