Greater Trochanteric Fixation Using a Cable System for Partial Hip Arthroplasty : A Clinical and Finite Element Analysis

المؤلفون المشاركون

Pekedis, Mahmut
Altay, Taşkın
Ozan, Fırat
Toker, Gökhan
Yıldız, Hasan
Koyuncu, Şemmi

المصدر

BioMed Research International

العدد

المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-7، 7ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2014-08-10

دولة النشر

مصر

عدد الصفحات

7

التخصصات الرئيسية

الطب البشري

الملخص EN

The aim of the study was to investigate the efficacy of greater trochanteric fixation using a multifilament cable to ensure abductor lever arm continuity in patients with a proximal femoral fracture undergoing partial hip arthroplasty.

Mean age of the patients (12 men, 20 women) was 84.12 years.

Mean follow-up was 13.06 months.

Fixation of the dislocated greater trochanter with or without a cable following load application was assessed by finite element analysis (FEA).

Radiological evaluation was based on the distance between the fracture and the union site.

Harris hip score was used to evaluate final results: outcomes were excellent in 7 patients (21.8%), good in 17 patients (53.1%), average in 5 patients (15.6%), and poor in 1 patient (9.3%).

Mean abduction angle was 20.21°.

Union was achieved in 14 patients (43.7%), fibrous union in 12 (37.5%), and no union in 6 (18.7%).

FEA showed that the maximum total displacement of the greater trochanter decreased when the fractured bone was fixed with a cable.

As the force applied to the cable increased, the displacement of the fractured trochanter decreased.

This technique ensures continuity of the abductor lever arm in patients with a proximal femoral fracture who are undergoing partial hip arthroplasty surgery.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Ozan, Fırat& Koyuncu, Şemmi& Pekedis, Mahmut& Altay, Taşkın& Yıldız, Hasan& Toker, Gökhan. 2014. Greater Trochanteric Fixation Using a Cable System for Partial Hip Arthroplasty : A Clinical and Finite Element Analysis. BioMed Research International،Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-509177

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Ozan, Fırat…[et al.]. Greater Trochanteric Fixation Using a Cable System for Partial Hip Arthroplasty : A Clinical and Finite Element Analysis. BioMed Research International No. 2014 (2014), pp.1-7.
https://search.emarefa.net/detail/BIM-509177

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Ozan, Fırat& Koyuncu, Şemmi& Pekedis, Mahmut& Altay, Taşkın& Yıldız, Hasan& Toker, Gökhan. Greater Trochanteric Fixation Using a Cable System for Partial Hip Arthroplasty : A Clinical and Finite Element Analysis. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-509177

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-509177