الملخص EN
An accurate assessment of the pulse depth in pulse diagnosis is vital to determine the floating and sunken pulse qualities (PQs), which are two of the four most basic PQs.
In this work, we proposed a novel model of assessing the pulse depth based on sensor displacement (SD) normal to the skin surface and compared this model with two previous models which assessed the pulse depth using contact pressure (CP).
In contrast to conventional stepwise CP variation tonometry, we applied a continuously evolving tonometric mechanism at a constant velocity and defined the pulse depth index as the optimal SD where the largest pulse amplitude was observed.
By calculating the pulse depth index for 18 volunteers, we showed that the pulse was deepest at Cheok (significance level: P<0.01), while no significant difference was found between Chon and Gwan.
In contrast, the two CP-based models estimated that the pulse was shallowest at Gwan (P<0.05).
For the repeated measures, the new SD-based model showed a smaller coefficient of variation (CV≈7.6%) than the two CP-based models (CV≈13.5% and 12.3%, resp.).
The SD-based pulse depth assessment is not sensitive to the complex geometry around the palpation locations and temperature variation of contact sensors, which allows cost-effective sensor technology.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Bae, Jang-Han& Jeon, Young Ju& Kim, Jong Yeol& Kim, Jaeuk U.. 2013. New Assessment Model of Pulse Depth Based on Sensor Displacement in Pulse Diagnostic Devices. Evidence-Based Complementary and Alternative Medicine،Vol. 2013, no. 2013, pp.1-9.
https://search.emarefa.net/detail/BIM-509779
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Bae, Jang-Han…[et al.]. New Assessment Model of Pulse Depth Based on Sensor Displacement in Pulse Diagnostic Devices. Evidence-Based Complementary and Alternative Medicine No. 2013 (2013), pp.1-9.
https://search.emarefa.net/detail/BIM-509779
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Bae, Jang-Han& Jeon, Young Ju& Kim, Jong Yeol& Kim, Jaeuk U.. New Assessment Model of Pulse Depth Based on Sensor Displacement in Pulse Diagnostic Devices. Evidence-Based Complementary and Alternative Medicine. 2013. Vol. 2013, no. 2013, pp.1-9.
https://search.emarefa.net/detail/BIM-509779
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-509779
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)