A protocol to choose the graft diameter attachment point of each bundle has not yet been determined since they are usually dependent on a surgeon’s preference.

Therefore, the influence of bundle diameters and attachment points on the kinematics of the knee joint needs to be quantitatively analyzed.

A three-dimensional knee model was reconstructed with computed tomography images of a 26-year-old man.

Based on the model, models of double bundle anterior cruciate ligament (ACL) reconstruction were developed.

The anterior tibial translations for the anterior drawer test and the internal tibial rotation for the pivot shift test were investigated according to variation of bundle diameters and attachment points.

For the model in this study, the knee kinematics after the double bundle ACL reconstruction were dependent on the attachment point and not much influenced by the bundle diameter although larger sized anterior-medial bundles provided increased stability in the knee joint.

Therefore, in the clinical setting, the bundle attachment point needs to be considered prior to the bundle diameter, and the current selection method of graft diameters for both bundles appears justified.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Kwon, Oh Soo& Purevsuren, Tserenchimed& Kim, Kyungsoo& Park, Won Man& Kwon, Tae-Kyu& Kim, Yoon Hyuk. 2014. Influence of Bundle Diameter and Attachment Point on Kinematic Behavior in Double Bundle Anterior Cruciate Ligament Reconstruction Using Computational Model. Computational and Mathematical Methods in Medicine،Vol. 2014, no. 2014, pp.1-8.
https://search.emarefa.net/detail/BIM-510548

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Kwon, Oh Soo…[et al.]. Influence of Bundle Diameter and Attachment Point on Kinematic Behavior in Double Bundle Anterior Cruciate Ligament Reconstruction Using Computational Model. Computational and Mathematical Methods in Medicine No. 2014 (2014), pp.1-8.
https://search.emarefa.net/detail/BIM-510548

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Kwon, Oh Soo& Purevsuren, Tserenchimed& Kim, Kyungsoo& Park, Won Man& Kwon, Tae-Kyu& Kim, Yoon Hyuk. Influence of Bundle Diameter and Attachment Point on Kinematic Behavior in Double Bundle Anterior Cruciate Ligament Reconstruction Using Computational Model. Computational and Mathematical Methods in Medicine. 2014. Vol. 2014, no. 2014, pp.1-8.
https://search.emarefa.net/detail/BIM-510548

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-510548