Influence of Bundle Diameter and Attachment Point on Kinematic Behavior in Double Bundle Anterior Cruciate Ligament Reconstruction Using Computational Model
المؤلفون المشاركون
Kim, Kyungsoo
Kim, Yoon Hyuk
Kwon, Oh Soo
Park, Won Man
Purevsuren, Tserenchimed
Kwon, Tae-Kyu
المصدر
Computational and Mathematical Methods in Medicine
العدد
المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-8، 8ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2014-01-05
دولة النشر
مصر
عدد الصفحات
8
التخصصات الرئيسية
الملخص EN
A protocol to choose the graft diameter attachment point of each bundle has not yet been determined since they are usually dependent on a surgeon’s preference.
Therefore, the influence of bundle diameters and attachment points on the kinematics of the knee joint needs to be quantitatively analyzed.
A three-dimensional knee model was reconstructed with computed tomography images of a 26-year-old man.
Based on the model, models of double bundle anterior cruciate ligament (ACL) reconstruction were developed.
The anterior tibial translations for the anterior drawer test and the internal tibial rotation for the pivot shift test were investigated according to variation of bundle diameters and attachment points.
For the model in this study, the knee kinematics after the double bundle ACL reconstruction were dependent on the attachment point and not much influenced by the bundle diameter although larger sized anterior-medial bundles provided increased stability in the knee joint.
Therefore, in the clinical setting, the bundle attachment point needs to be considered prior to the bundle diameter, and the current selection method of graft diameters for both bundles appears justified.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Kwon, Oh Soo& Purevsuren, Tserenchimed& Kim, Kyungsoo& Park, Won Man& Kwon, Tae-Kyu& Kim, Yoon Hyuk. 2014. Influence of Bundle Diameter and Attachment Point on Kinematic Behavior in Double Bundle Anterior Cruciate Ligament Reconstruction Using Computational Model. Computational and Mathematical Methods in Medicine،Vol. 2014, no. 2014, pp.1-8.
https://search.emarefa.net/detail/BIM-510548
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Kwon, Oh Soo…[et al.]. Influence of Bundle Diameter and Attachment Point on Kinematic Behavior in Double Bundle Anterior Cruciate Ligament Reconstruction Using Computational Model. Computational and Mathematical Methods in Medicine No. 2014 (2014), pp.1-8.
https://search.emarefa.net/detail/BIM-510548
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Kwon, Oh Soo& Purevsuren, Tserenchimed& Kim, Kyungsoo& Park, Won Man& Kwon, Tae-Kyu& Kim, Yoon Hyuk. Influence of Bundle Diameter and Attachment Point on Kinematic Behavior in Double Bundle Anterior Cruciate Ligament Reconstruction Using Computational Model. Computational and Mathematical Methods in Medicine. 2014. Vol. 2014, no. 2014, pp.1-8.
https://search.emarefa.net/detail/BIM-510548
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-510548
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر