Influence of Electrode Placement on Signal Quality for Ambulatory Pregnancy Monitoring

المؤلفون المشاركون

Rooijakkers, Michael Johannes
Bergmans, J. W. M.
Cantatore, E.
Song, S.
Mischi, Massimo
Rabotti, Chiara
Oei, S. Guid

المصدر

Computational and Mathematical Methods in Medicine

العدد

المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-12، 12ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2014-02-03

دولة النشر

مصر

عدد الصفحات

12

التخصصات الرئيسية

الطب البشري

الملخص EN

Noninvasive fetal health monitoring during pregnancy has become increasingly important in order to prevent complications, such as fetal hypoxia and preterm labor.

With recent advances in signal processing technology using abdominal electrocardiogram (ECG) recordings, ambulatory fetal monitoring throughout pregnancy is now an important step closer to becoming feasible.

The large number of electrodes required in current noise-robust solutions, however, leads to high power consumption and reduced patient comfort.

In this paper, requirements for reliable fetal monitoring using a minimal number of electrodes are determined based on simulations and measurement results.

To this end, a dipole-based model is proposed to simulate different electrode positions based on standard recordings.

Results show a significant influence of bipolar lead orientation on maternal and fetal ECG measurement quality, as well as a significant influence of interelectrode distance for all signals of interest.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Rooijakkers, Michael Johannes& Song, S.& Rabotti, Chiara& Oei, S. Guid& Bergmans, J. W. M.& Cantatore, E.…[et al.]. 2014. Influence of Electrode Placement on Signal Quality for Ambulatory Pregnancy Monitoring. Computational and Mathematical Methods in Medicine،Vol. 2014, no. 2014, pp.1-12.
https://search.emarefa.net/detail/BIM-511639

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Rooijakkers, Michael Johannes…[et al.]. Influence of Electrode Placement on Signal Quality for Ambulatory Pregnancy Monitoring. Computational and Mathematical Methods in Medicine No. 2014 (2014), pp.1-12.
https://search.emarefa.net/detail/BIM-511639

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Rooijakkers, Michael Johannes& Song, S.& Rabotti, Chiara& Oei, S. Guid& Bergmans, J. W. M.& Cantatore, E.…[et al.]. Influence of Electrode Placement on Signal Quality for Ambulatory Pregnancy Monitoring. Computational and Mathematical Methods in Medicine. 2014. Vol. 2014, no. 2014, pp.1-12.
https://search.emarefa.net/detail/BIM-511639

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-511639