OBJECTIVE: to identify the effect of noise in the NICU on neonate's hearing status, and to assess the value of using hearing protectors (e.g.
earplug and earmuff) to minimize the effect of noise on these neonates.
METHODS: '634' newborns were divided into two groups, the control group (n= 395) and the study (n^ 239).
The noise level inside and outside incubators was measured by using sound level meter.
Neonates in both groups were tested for hearing by transient evoked otoacoustic emissions (TEOAE) test on admission.
The study group of neonates worn ear protectors from admission to discharge while the control group did not.
Transient Evoked Otoacoustic Emission test was repeated for both groups on discharge.
Any infant who didn't pass the test on discharge was reevaluated 2 months later and in case of new failure, the test was repeated at 4 months of the infant's age.
RESULTS .'Statistically significant differences were found between infants in both groups regarding TEOAE test results either at discharge or at the first follow-up with a higher percentage of failed tests among infants in the unprotected control group.
Also, the prevalence of failed ear response was higher in neonates were exposed to noise 45 dB or more than those exposed to noise level < 45 dB.
It was noticed that mean duration of hospital stays was shorter in the study group than in the control group (8.9 VS 13.7).
CONCLUSION: Environmental noise in the NICU has potential adverse effect on neonate's hearing status.
Noise induced hearing loss in NICU is mostly transient and reversible.
Using ear protectors were useful in reducing the hazardous effect of noise on hearing sense in neonates in NICU
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Bakr, Muhammad Salamah& Muhammad, Samiyah A.& Dabsh, Suhayr Abd al-Hamid& Ahmad, Awatif al-Sayyid& Marzuq, Salwa Ali. 2005. A study on the effect of hearing protectors on newborns admitted to the neonatal intensive care unit (NICU) for prevention of acquired hearing disorders. Assiut Medical Journal،Vol. 29, no. 3, pp.235-246.
https://search.emarefa.net/detail/BIM-51389
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Bakr, Muhammad Salamah…[et al.]. A study on the effect of hearing protectors on newborns admitted to the neonatal intensive care unit (NICU) for prevention of acquired hearing disorders. Assiut Medical Journal Vol. 29, no. 3 (Sep. 2005), pp.235-246.
https://search.emarefa.net/detail/BIM-51389
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Bakr, Muhammad Salamah& Muhammad, Samiyah A.& Dabsh, Suhayr Abd al-Hamid& Ahmad, Awatif al-Sayyid& Marzuq, Salwa Ali. A study on the effect of hearing protectors on newborns admitted to the neonatal intensive care unit (NICU) for prevention of acquired hearing disorders. Assiut Medical Journal. 2005. Vol. 29, no. 3, pp.235-246.
https://search.emarefa.net/detail/BIM-51389
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references : p. 245-246
رقم السجل
BIM-51389
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)