![](/images/graphics-bg.png)
Application of Principal Component Analysis in Automatic Localization of Optic Disc and Fovea in Retinal Images
المؤلفون المشاركون
Butt, Saira
Mudassar, Asloob Ahmad
المصدر
Journal of Medical Engineering
العدد
المجلد 2013، العدد 2013 (31 ديسمبر/كانون الأول 2013)، ص ص. 1-12، 12ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2013-05-23
دولة النشر
مصر
عدد الصفحات
12
التخصصات الرئيسية
الملخص EN
A retinal image has blood vessels, optic disc, fovea, and so forth as the main components of an image.
Segmentation of these components has been investigated extensively.
Principal component analysis (PCA) is one of the techniques that have been applied to segment the optic disc, but only a limited work has been reported.
To our knowledge, fovea segmentation problem has not been reported in the literature using PCA.
In this paper, we are presenting the segmentation of optic disc and fovea using PCA.
The PCA was trained on optic discs and foveae using ten retinal images and then applied on seventy retinal images with a success rate of 97% in case of optic discs and 94.3% in case of fovea.
Conventional algorithms feed one patch at a time from a test retinal image, and the next patch separated by one pixel part is fed.
This process is continued till the full image area is covered.
This is time consuming.
We are suggesting techniques to cut down the processing time with the help of binary vessel tree of a given test image.
Results are presented to validate our idea.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Mudassar, Asloob Ahmad& Butt, Saira. 2013. Application of Principal Component Analysis in Automatic Localization of Optic Disc and Fovea in Retinal Images. Journal of Medical Engineering،Vol. 2013, no. 2013, pp.1-12.
https://search.emarefa.net/detail/BIM-514024
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Mudassar, Asloob Ahmad& Butt, Saira. Application of Principal Component Analysis in Automatic Localization of Optic Disc and Fovea in Retinal Images. Journal of Medical Engineering No. 2013 (2013), pp.1-12.
https://search.emarefa.net/detail/BIM-514024
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Mudassar, Asloob Ahmad& Butt, Saira. Application of Principal Component Analysis in Automatic Localization of Optic Disc and Fovea in Retinal Images. Journal of Medical Engineering. 2013. Vol. 2013, no. 2013, pp.1-12.
https://search.emarefa.net/detail/BIM-514024
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-514024
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)