Evaluationof curing depth of bulk-fill resin composite : a comparative study

المؤلفون المشاركون

Ibrahim, Muhammad A.
al-Araji, Salam A.
Rajab, Halah A.

المصدر

Medical Journal of Babylon

العدد

المجلد 12، العدد 1 (31 مارس/آذار 2015)، ص ص. 325-331، 7ص.

الناشر

جامعة بابل كلية الطب

تاريخ النشر

2015-03-31

دولة النشر

العراق

عدد الصفحات

7

التخصصات الرئيسية

طب الأسنان

الموضوعات

الملخص EN

-This study evaluated the depth of cure (DOC) of recently introduced resin composites for posterior use, bulk filled flowable composite (SureFil® SDR® flow DENTSPLY Caulk) at different depth.

30 specimens were prepared and divided into two Groups,Group 1: specimens with 2 mm depth, Group 2: specimens with 4mm depth.

The composite specimens were prepared by using molds of different depth, one of them with was a hole of 4 mm depth and 4 mm internal diameter and the other was with a depth of 2 mm at the same diameter.

The hole was bulk filled with SDR flowable composite resin and light cured for 20 seconds with a modern high-intensity LED curing unit (Elipar™ S10, 3M.US.), followed by 24 hours storage in complete darkness incubator at 37 C◦.

The degree of conversion was measured on the top and the bottom for both depths using Fourier transform infrared (FTIR) spectroscopy.

A bulk filled flowable (SDR)revealed a significant difference in degree of conversion (DOC) when the bottom surface of the specimen witha 2mm depth (DOC=76.27112163) wascompared with the bottom surface of the 4mm depth specimen (DOC=73.92160935).

The 2mm depth wasshown statistically significantly higher mean values degree of conversion than 4 mm depth (P-value = 0.032).

There was no statistically significant difference in the degree of conversion mean values between the top and the bottom surfaces of the specimen of the same group (P >0.05).

Upon the result of thisin vitro study, it was found that the degree of conversion of the SDR bulk-fill flowable resin compositewasaffected by depths.

As the depth of the resin compositewas increased the degree of conversion was decreased.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

al-Araji, Salam A.& Ibrahim, Muhammad A.& Rajab, Halah A.. 2015. Evaluationof curing depth of bulk-fill resin composite : a comparative study. Medical Journal of Babylon،Vol. 12, no. 1, pp.325-331.
https://search.emarefa.net/detail/BIM-549964

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

al-Araji, Salam A.…[et al.]. Evaluationof curing depth of bulk-fill resin composite : a comparative study. Medical Journal of Babylon Vol. 12, no. 1 (2015), pp.325-331.
https://search.emarefa.net/detail/BIM-549964

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

al-Araji, Salam A.& Ibrahim, Muhammad A.& Rajab, Halah A.. Evaluationof curing depth of bulk-fill resin composite : a comparative study. Medical Journal of Babylon. 2015. Vol. 12, no. 1, pp.325-331.
https://search.emarefa.net/detail/BIM-549964

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references : p. 331

رقم السجل

BIM-549964