![](/images/graphics-bg.png)
Optical study on adaptive cassegrain telescope
العناوين الأخرى
دراسة بصرية لتلسكوب كاسكرين التكيفي
مقدم أطروحة جامعية
مشرف أطروحة جامعية
الجامعة
جامعة بغداد
الكلية
كلية العلوم
القسم الأكاديمي
قسم الفلك و الفضاء
دولة الجامعة
العراق
الدرجة العلمية
دكتوراه
تاريخ الدرجة العلمية
2007
الملخص الإنجليزي
In manufacturing an adaptive mirror for use, for example, in a typical adaptive astronomical telescope, actuator and mirror design are constrained by optical, electrical and mechanical trade-offs and manufacturing process limitations.
For a certain optical design, however, the designer must have beforehand feeling of how Zernike coefficients values that are utilized by the control algorithm can affect the creation of an adequate conjugate shape on the adaptive mirror.
The main goal of this research is to obtain this feeling by examining the Zernike coefficients of an aberrated image wave-front for a typical Cassegrain system, and utilizing them to show the feasibility of designing and constructing the desired adaptive mirror.
First, several Cassegrains of different focal ratios but of the same primary (2.167m) are proposed.
Then the performance is examined by using Qbasic program.
Six cases of shortest back focal lengths but of different F1/# are thoroughly examined by employing Zemax software.
The performance of these six cases is re-examined by adding Zernike coefficients on their secondary profiles.
Second, work was concentrated on examining the performance of 2.5F1/# configuration of different secondary mirror sizes.
A configuration of 0.65 m secondary hyperbolic mirror employing eleven Zernike coefficients Z1 ,Z2 ,Z3 ,Z4 ,Z5 ,Z6 ,Z7 ,Z8 ,Z9 ,Z10 and Z11 shows a diffraction limited performance.
For F1#5 system with Zernike coefficients Z1=0.000021, Z4=0.000012 and Z11=0, the Strehl Ratio and RMS radius was 1 and 0.001 respectively.
Varying the secondary mirror dimension resulting in increasing or decreasing the coefficients values by the same scaling factor.
التخصصات الرئيسية
الموضوعات
عدد الصفحات
93
قائمة المحتويات
Table of contents.
Abstract.
Abstract in Arabic.
Chapter One : Introduction.
Chapter Two : Adaptive optics.
Chapter Three : Conventional cassegrain mirrors.
Chapter Four : Adaptive study on cassegrainian.
Chapter Five : Conclusions and future work.
References.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Ali, Shruq Mahdi. (2007). Optical study on adaptive cassegrain telescope. (Master's theses Theses and Dissertations Master). University of Baghdad, Iraq
https://search.emarefa.net/detail/BIM-604476
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Ali, Shruq Mahdi. Optical study on adaptive cassegrain telescope. (Master's theses Theses and Dissertations Master). University of Baghdad. (2007).
https://search.emarefa.net/detail/BIM-604476
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Ali, Shruq Mahdi. (2007). Optical study on adaptive cassegrain telescope. (Master's theses Theses and Dissertations Master). University of Baghdad, Iraq
https://search.emarefa.net/detail/BIM-604476
لغة النص
الإنجليزية
نوع البيانات
رسائل جامعية
رقم السجل
BIM-604476
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)