Stretch polytetrafluoroethylene grafts for hemodialysis angioaccess three-year experience

المؤلفون المشاركون

al-Zahrani, Said
al-Urayfi, Ibrahim
al-Dayil, Adil G.
Ezzibdeh, Mamun Y.
Ujay, Sadiq Adam
al-Sayyid, Isam
Abu Zallat, Ali

المصدر

Saudi Journal of Kidney Diseases and Transplantation

العدد

المجلد 12، العدد 2 (30 إبريل/نيسان 2001)، ص ص. 172-174، 3ص.

الناشر

المركز السعودي لزراعة الأعضاء

تاريخ النشر

2001-04-30

دولة النشر

السعودية

عدد الصفحات

3

التخصصات الرئيسية

الطب البشري

الموضوعات

الملخص EN

We report the results of 90 stretch polytetrafluoroethylene (PTFE) grafts in 78 chronic renal failure patients over a 3-year period from 1995-1998.

The grafts were used as primary access in 15 % of the patients.

The cumulative patency was 63.3 % and there were no complications in 48.8 % of the cases.

Infection was encountered in 15.5 % and thrombosis in 31.1 % of the grafts.

Intimal hyperplasia, venous anastomotic stenosis, improper puncture technique and subclavian vein stenosis were the major causes of failure of grafts.

We conclude that stretch PTFE grafts as angioaccesses may provide good patency and durability.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

al-Dayil, Adil G.& al-Urayfi, Ibrahim& Ezzibdeh, Mamun Y.& Ujay, Sadiq Adam& al-Sayyid, Isam& Abu Zallat, Ali…[et al.]. 2001. Stretch polytetrafluoroethylene grafts for hemodialysis angioaccess three-year experience. Saudi Journal of Kidney Diseases and Transplantation،Vol. 12, no. 2, pp.172-174.
https://search.emarefa.net/detail/BIM-60742

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

al-Urayfi, Ibrahim…[et al.]. Stretch polytetrafluoroethylene grafts for hemodialysis angioaccess three-year experience. Saudi Journal of Kidney Diseases and Transplantation Vol. 12, no. 2 (Apr. 2001), pp.172-174.
https://search.emarefa.net/detail/BIM-60742

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

al-Dayil, Adil G.& al-Urayfi, Ibrahim& Ezzibdeh, Mamun Y.& Ujay, Sadiq Adam& al-Sayyid, Isam& Abu Zallat, Ali…[et al.]. Stretch polytetrafluoroethylene grafts for hemodialysis angioaccess three-year experience. Saudi Journal of Kidney Diseases and Transplantation. 2001. Vol. 12, no. 2, pp.172-174.
https://search.emarefa.net/detail/BIM-60742

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references : p. 174

رقم السجل

BIM-60742