Background : The main aim of the present study is to qualify and quantify voids formation of root canals obturated with GuttaCore (GC) and experimental Hydroxyapatite polyethylene (HA/PE) as new carrier-based root canal fillings by using micro computed tomography scan.

Materials and methods: In the present study, eight straight single-rooted human permanent premolar teeth are selected and disinfected, then stored in distilled water.

The teeth decoronated leaving a root length of 12mm each.

The root canals instrumented by using crown down technique and the apical diameter of the root canal prepared to a size # 30 / 0.04 for achieving standardized measurements.

A 5mL of 17 % EDTA used to remove the smear layer followed by 5mL of 2.5 % NaOCl and rinsing with normal saline.

Then the shaped root canals were randomly subdivided into two groups of 4 teeth each according to the carrier-based obturation system use, GuttaCore or experimental HA/PE.

Afterwards, the obturated roots stored at 37°C with 100% humidity for 72 hours to allow for complete setting of the sealer.

Micro-CT was then scanned to quantify the voids within the root canal space.

The data were statistically analyzed by one-way ANOVA and post hoc comparison tests (α=0.05).

Results: The root canals obturated with both obturation systems, GuttaCore andexperimental HA/PE showed voids formation, particularly at the apical third of the root canal.

GC obturation showed a lower percentage of voids volume (1.54 %) than the experimental HA/PE obturation (2.3 %).

The void volume percentage in the GuttaCore system, however, was non-significantly different (P> 0.05) in comparison with the experimental PE/HA system.

Conclusions : GuttaCore and experimental HA/PE obturators exhibited voids formation within the entire root canal space.

The experimental HA/PE obturator is comparable to the GuttaCore obturator in terms of voids qualification

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

al-Hashimi, Raghad A.. 2015. A micro computed tomography assessment of new carrier-based root canal fillings. Journal of Baghdad College of Dentistry،Vol. 27, no. 4, pp.21-24.
https://search.emarefa.net/detail/BIM-651153

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

al-Hashimi, Raghad A.. A micro computed tomography assessment of new carrier-based root canal fillings. Journal of Baghdad College of Dentistry Vol. 27, no. 4 (Dec. 2015), pp.21-24.
https://search.emarefa.net/detail/BIM-651153

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

al-Hashimi, Raghad A.. A micro computed tomography assessment of new carrier-based root canal fillings. Journal of Baghdad College of Dentistry. 2015. Vol. 27, no. 4, pp.21-24.
https://search.emarefa.net/detail/BIM-651153

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references : p. 24

رقم السجل

BIM-651153