The effect of led light on depth of cure and microhardness of three types of bulkfill composite

المؤلفون المشاركون

Muhannad R. A.
Baban, Lama M. S.

المصدر

Journal of Baghdad College of Dentistry

العدد

المجلد 28، العدد 1 (31 مارس/آذار 2016)، ص ص. 36-40، 5ص.

الناشر

جامعة بغداد كلية طب الأسنان

تاريخ النشر

2016-03-31

دولة النشر

العراق

عدد الصفحات

5

التخصصات الرئيسية

الكيمياء

الملخص EN

Background: To evaluate the ISO depth of cure of bulkfill composites and depth of cure which determined by Vickers microhardness test.

Materials and Methods: Bulkfill resin composite specimens (n=150) were prepared of three bulkfill composite materials (TetricEvo Ceram, Quixfil and SDR) and light cured by Flash max p3 for 3, 10, 20 seconds and by wood pecker for 10, 20 seconds respectively, a mold was filled with one of the three bulkfill composites and light cured.

The specimens removed from the mold and scraped by plastic spatula and the remaining length (absolute length) was measured which represent the ISO depth of cure.

After that the specimens were returned into the mold and a microhardness indentation device applied on the specimen and hardness measurements (Vickers hardness, VHN) were made at defined distance, beginning at the resin composite that had been closest to the light curing unit (i.e.

at the top) and proceeding toward the uncured resin composite (i.e.

toward the bottom) on the basis of the VHN measurement, Vickers hardness test generated for each group.

Results and Conclusion: ISO depth of cure of bulkfill composite materials is time and type of light curing protocol dependent rather than type of material of bulkfill composite while the depth of cure determined by Vickers hardness number is material dependent in addition to the light curing protocol.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Muhannad R. A.& Baban, Lama M. S.. 2016. The effect of led light on depth of cure and microhardness of three types of bulkfill composite. Journal of Baghdad College of Dentistry،Vol. 28, no. 1, pp.36-40.
https://search.emarefa.net/detail/BIM-683359

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Muhannad R. A.& Baban, Lama M. S.. The effect of led light on depth of cure and microhardness of three types of bulkfill composite. Journal of Baghdad College of Dentistry Vol. 28, no. 1 (Mar. 2016), pp.36-40.
https://search.emarefa.net/detail/BIM-683359

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Muhannad R. A.& Baban, Lama M. S.. The effect of led light on depth of cure and microhardness of three types of bulkfill composite. Journal of Baghdad College of Dentistry. 2016. Vol. 28, no. 1, pp.36-40.
https://search.emarefa.net/detail/BIM-683359

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references : p. 40

رقم السجل

BIM-683359