Insertion characteristics of three supraglottic airway devices : a randomized comparative trial
المؤلف
المصدر
Ain Shams Journal of Anesthesiology
العدد
المجلد 9، العدد 2 (30 يونيو/حزيران 2016)، ص ص. 212-218، 7ص.
الناشر
جامعة عين شمس كلية الطب قسم التخدير
تاريخ النشر
2016-06-30
دولة النشر
مصر
عدد الصفحات
7
التخصصات الرئيسية
الموضوعات
الملخص EN
Background I-gel is a new single-use supraglottic airway device without an infl atable cuff.
The aim of this study was to compare I-gel, a Proseal laryngeal mask airway ( PLMA), and a laryngeal tube (LT) for ease of insertion, hemodynamic effects of insertion, and associated airway morbidity.
Patients and methods Seventy-fi ve adult patients, both sexes, were assigned randomly to I-gel (I), PLMA (P), and LT (L) groups according to the supraglottic device applied.
Insertion time, airway sealing pressure, insertion success rate, insertion-associated hemodynamic effects, ease of gastric tube insertion, and associated airway morbidities were assessed.
Results Demographic data and duration of both surgery and anesthesia in the three groups were comparable.
Insertion time (s) was signifi cantly shorter in group I (18.9 ± 0.9) compared with group P (26.2 ± 1.1) and group L (26.2 ± 1.0).
Airway sealing pressure ( cm H2O) was higher in group P (29.6 ± 1.2) compared with group I (26.0 ± 1.0) and group L (22.9 ± 0.9).
The success rate at the fi rst insertion attempt was higher in group I (96.0 %) compared with group P (84.0 %) and group L (88 %).
Blood-stained devices and occurrence of postoperative sore throat were lower in group I than the P and L group, with no signifi cant differences.
Heart rat e, mean arterial pressure, and cardiac index were signifi cantly increased in the postinsertion period in the P and L group compared with group I.
Conclusion In the I-gel group, higher insertion success rate, and lower both hemodynamic changes and airway morbidities were noted compared with PLMA and LT.
However, airway sealing ability was better with PLMA
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Sulayman, Hisham F.. 2016. Insertion characteristics of three supraglottic airway devices : a randomized comparative trial. Ain Shams Journal of Anesthesiology،Vol. 9, no. 2, pp.212-218.
https://search.emarefa.net/detail/BIM-688295
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Sulayman, Hisham F.. Insertion characteristics of three supraglottic airway devices : a randomized comparative trial. Ain Shams Journal of Anesthesiology Vol. 9, no. 2 (Apr. / Jun. 2016), pp.212-218.
https://search.emarefa.net/detail/BIM-688295
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Sulayman, Hisham F.. Insertion characteristics of three supraglottic airway devices : a randomized comparative trial. Ain Shams Journal of Anesthesiology. 2016. Vol. 9, no. 2, pp.212-218.
https://search.emarefa.net/detail/BIM-688295
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references : p. 217-218
رقم السجل
BIM-688295
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر