الملخص EN
Background and objective The aim of this study was to know whether colloid fl uid administration (either preloading or coloading) can decrease the incidence of hypotension secondary to spinal anesthesia in an elderly population undergoing inguinal hernia repair without mesh.
Patients and methods After obtaining institutional ethical committee’s approval and patients’ informed consent, 84 patients (aged 61–89 years) scheduled for elective inguinal hernia repair were enrolled in this prospective, randomized study.
We compared the incidence of hypotension and ephedrine requirement after spinal anesthesia between three groups: group P (n = 28), in which patients were preloaded with 500 ml of 6% hydroxyethyl starch solution (130/0.4), group C (n = 28), in which patients were coloaded with 6% hydroxyethyl starch solution during spinal anesthesia, and group N (n = 28), in which patients were not given any fl uid.
Results The incidence of hypotension and the mean dose of ephedrine were not signifi cantly different between the three groups.
Conclusion We concluded that, in elderly patients undergoing inguinal hernia repair, withholding fl uid loading (whether preloading or coloading) did not increase the incidence of spinal anesthesiainduced hypotension and did not affect the dose of ephedrine required to correct hypotension, if occurred.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Ulaywah, Jamal M.& Labib, Hibah A.& Samir, Ghadah M.. 2016. Comparison between colloid preload, colloid, and no load in the prevention of spinal anesthesia-induced hypotension in patients undergoing inguinal hernia repair. Ain Shams Journal of Anesthesiology،Vol. 9, no. 2, pp.250-255.
https://search.emarefa.net/detail/BIM-688347
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Ulaywah, Jamal M.…[et al.]. Comparison between colloid preload, colloid, and no load in the prevention of spinal anesthesia-induced hypotension in patients undergoing inguinal hernia repair. Ain Shams Journal of Anesthesiology Vol. 9, no. 2 (Apr. / Jun. 2016), pp.250-255.
https://search.emarefa.net/detail/BIM-688347
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Ulaywah, Jamal M.& Labib, Hibah A.& Samir, Ghadah M.. Comparison between colloid preload, colloid, and no load in the prevention of spinal anesthesia-induced hypotension in patients undergoing inguinal hernia repair. Ain Shams Journal of Anesthesiology. 2016. Vol. 9, no. 2, pp.250-255.
https://search.emarefa.net/detail/BIM-688347
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references : p. 245-255
رقم السجل
BIM-688347
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)