Performance of grid connected DFIG during recurring symmetrical faults using internal model controller based enhanced field oriented control

المؤلفون المشاركون

Ananth, D. V. N.
Kumar, G. V. Nagesh

المصدر

Journal of Electrical Systems

العدد

المجلد 12، العدد 2 (30 يونيو/حزيران 2016)، ص ص. 406-418، 13ص.

الناشر

دار النجم الثاقب

تاريخ النشر

2016-06-30

دولة النشر

الجزائر

عدد الصفحات

13

التخصصات الرئيسية

الهندسة الكهربائية

الموضوعات

الملخص EN

The modern grid rules forces DFIG to withstand and operate during single as well as multiple low voltage grid faults.

The system must not lose synchronism during any type of fault for a given time period.

This withstanding capacity is called low voltage ride through (LVRT).

To improve performance during LVRT, enhanced field oriented control (EFOC) method is adopted in rotor side converter.

This method helps in improving power transfer capability during steady state and better dynamic and transient stability during abnormal conditions.

In this technique, rotor flux reference change from synchronous speed to some smaller speed or zero during the fault for injecting current at the rotor slip frequency.

In this process, DC-Offset component of flux is controlled beyond decomposing to a lower value during faults and maintaining it.

This offset decomposition of flux will be oscillatory in conventional FOC, whereas in EFOC with internal model controller, flux can damp quickly not only for single fault but during multiple faults.

This strategy can regulate stator and rotor current waveform to sinusoidal without distortion during and after fault.

It has better damped torque oscillations, control in rotor speed and generator flux during and after fault.

The fluctuations in DC bus voltage across capacitor are also controlled using proposed EFOC technique.

The system performance with under-voltage grid fault of 30 % and 60% of the rated voltage occurring at the point of common coupling during 1 to 1.25 and another fault between 1.6 to 1.85 seconds are analyzed using simulation studies.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Ananth, D. V. N.& Kumar, G. V. Nagesh. 2016. Performance of grid connected DFIG during recurring symmetrical faults using internal model controller based enhanced field oriented control. Journal of Electrical Systems،Vol. 12, no. 2, pp.406-418.
https://search.emarefa.net/detail/BIM-689842

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Ananth, D. V. N.& Kumar, G. V. Nagesh. Performance of grid connected DFIG during recurring symmetrical faults using internal model controller based enhanced field oriented control. Journal of Electrical Systems Vol. 12, no. 2 (2016), pp.406-418.
https://search.emarefa.net/detail/BIM-689842

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Ananth, D. V. N.& Kumar, G. V. Nagesh. Performance of grid connected DFIG during recurring symmetrical faults using internal model controller based enhanced field oriented control. Journal of Electrical Systems. 2016. Vol. 12, no. 2, pp.406-418.
https://search.emarefa.net/detail/BIM-689842

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references : p. 418

رقم السجل

BIM-689842