Numerical and experimental study of the performance of electromagnetic flowmeter in annular flow

المؤلفون المشاركون

Jawad, İhsan Nazim
Ismail, Munir Abd al-Jalil

المصدر

Basrah Journal for Engineering Sciences

العدد

المجلد 14، العدد 2 (31 ديسمبر/كانون الأول 2014)، ص ص. 122-136، 15ص.

الناشر

جامعة البصرة كلية الهندسة

تاريخ النشر

2014-12-31

دولة النشر

العراق

عدد الصفحات

15

التخصصات الرئيسية

الفيزياء

الملخص EN

The present numerical and experimental work investigates the performance of electromagnetic flowmeter (EMF) for measuring the flow rate of annular flow.

Adaptive finite difference technique is used for the numerical calculations and the experimental work is done by making some modification on an existing electromagnetic flowmeter and its testing rig.

The performance of the modified EMF is evaluated using two criteria namely, the flowmeter sensitivity S and the conventional weight function non uniformity ε.

These two criteria were checked against two parameters; thickness of flowing water (δ) and the electrodes angular position (θe).

Experimentally, three different water thickness (δ/Ro = 0.216, 0.373, 0.218) and three electrode position (θe=0o, 11.25o, 45o) were studied.

The theoretical and experimental results have showed that these devices work properly in the annular flow case, where the most suitable electrode position in the annular flow was found to be in the conventional position (θe =0o).

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Jawad, İhsan Nazim& Ismail, Munir Abd al-Jalil. 2014. Numerical and experimental study of the performance of electromagnetic flowmeter in annular flow. Basrah Journal for Engineering Sciences،Vol. 14, no. 2, pp.122-136.
https://search.emarefa.net/detail/BIM-697185

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Jawad, İhsan Nazim& Ismail, Munir Abd al-Jalil. Numerical and experimental study of the performance of electromagnetic flowmeter in annular flow. Basrah Journal for Engineering Sciences Vol. 14, no. 2 (2014), pp.122-136.
https://search.emarefa.net/detail/BIM-697185

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Jawad, İhsan Nazim& Ismail, Munir Abd al-Jalil. Numerical and experimental study of the performance of electromagnetic flowmeter in annular flow. Basrah Journal for Engineering Sciences. 2014. Vol. 14, no. 2, pp.122-136.
https://search.emarefa.net/detail/BIM-697185

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes appendix : p. 128-136

رقم السجل

BIM-697185