A case study on fault detection in power transformers using dissolved gas analysis and electrical test methods
المؤلف
المصدر
العدد
المجلد 12، العدد 3 (30 سبتمبر/أيلول 2016)، ص ص. 442-459، 18ص.
الناشر
تاريخ النشر
2016-09-30
دولة النشر
الجزائر
عدد الصفحات
18
التخصصات الرئيسية
الملخص EN
This paper presents methodologies for power transformer fault diagnosis using dissolved gas analysis and electrical test methods.
These methods are widely used in determination of inception faults of power transformers.
Dissolved gas analysis test provides fault diagnosis of power transformers.
On the other hand the electrical test methods are used for detection of root causes and fault locations and they provide more specific information about the faults.
The aim of this work is to study the faults that are measured and recorded in Turkish Electricity Transmission Company (TEIAS) power systems.
For this purpose, four specific cases are considered and analyzed with dissolved gas analysis and electrical testing methods.
Three of these cases are defective situations and one case is a non-defective situation.
These real cases of measurements have been analyzed with both methods in detail.
Assessment results showed that a single method cannot yield accurate enough results in some specific fault conditions.
Therefore it was concluded that cooperation of both methods in the assessment of fault condition gives more trustworthy results.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Koroglu, Selim. 2016. A case study on fault detection in power transformers using dissolved gas analysis and electrical test methods. Journal of Electrical Systems،Vol. 12, no. 3, pp.442-459.
https://search.emarefa.net/detail/BIM-707951
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Koroglu, Selim. A case study on fault detection in power transformers using dissolved gas analysis and electrical test methods. Journal of Electrical Systems Vol. 12, no. 3 (Sep. 2016), pp.442-459.
https://search.emarefa.net/detail/BIM-707951
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Koroglu, Selim. A case study on fault detection in power transformers using dissolved gas analysis and electrical test methods. Journal of Electrical Systems. 2016. Vol. 12, no. 3, pp.442-459.
https://search.emarefa.net/detail/BIM-707951
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references : p. 458-459
رقم السجل
BIM-707951
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر