The effect of 99mo production on the neutronic safety parameters of research reactors

المؤلفون المشاركون

Rafat, Riham M.
Louis, Hibah K.

المصدر

Arab Journal of Nuclear Sciences and Applications

العدد

المجلد 47، العدد 1 (28 فبراير/شباط 2014)، ص ص. 145-153، 9ص.

الناشر

الجمعية المصرية للعلوم النووية و تطبيقاتها

تاريخ النشر

2014-02-28

دولة النشر

مصر

عدد الصفحات

9

التخصصات الرئيسية

الفيزياء
الكيمياء

الملخص EN

One of the main purposes of research reactors is the production of radioisotopes for medicine, industry and research activities.

99mTc is one of these radioisotopes, it is generated from the radioactive decay of 99Mo and it is supplied to hospitals as 99Mo/99mTc generators.

The most available and efficient route for obtaining the high specific activity 99Mo required for the 99mTc generators is the separation from fission products resulting from the irradiation of 235U targets in research reactors.

The aim of this paper is to present the neutronic calculations performed to study the effect of introducing an Irradiation Device for 99Mo Production into a research reactor core utilized for fuel irradiation.

Also the operational conditions with the presence of the irradiation device for 99Mo production from low enriched fuel irradiated in a research reactor are verified.

Calculations are carried out in order to evaluate all core neutronic parameters to assure that the core load satisfies all safety design criteria.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Rafat, Riham M.& Louis, Hibah K.. 2014. The effect of 99mo production on the neutronic safety parameters of research reactors. Arab Journal of Nuclear Sciences and Applications،Vol. 47, no. 1, pp.145-153.
https://search.emarefa.net/detail/BIM-724203

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Rafat, Riham M.& Louis, Hibah K.. The effect of 99mo production on the neutronic safety parameters of research reactors. Arab Journal of Nuclear Sciences and Applications Vol. 47, no. 1 (Feb. 2014), pp.145-153.
https://search.emarefa.net/detail/BIM-724203

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Rafat, Riham M.& Louis, Hibah K.. The effect of 99mo production on the neutronic safety parameters of research reactors. Arab Journal of Nuclear Sciences and Applications. 2014. Vol. 47, no. 1, pp.145-153.
https://search.emarefa.net/detail/BIM-724203

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references : p. 153

رقم السجل

BIM-724203