Calculation of the total mass stopping power for electrons in some human body tissues in the energy range 0.01-1000 MeV
العناوين الأخرى
حساب قدرة الإيقاف الكلية للإلكترونات لبعض أجزاء الجسم البشري في مدى الطاقة من 0.01 إلى 1000 مليون إلكترون فولت
المؤلفون المشاركون
Mahdi, Janan Fadil
Kamun, Said Salman
المصدر
العدد
المجلد 15، العدد 34 (31 ديسمبر/كانون الأول 2017)، ص ص. 72-80، 9ص.
الناشر
تاريخ النشر
2017-12-31
دولة النشر
العراق
عدد الصفحات
9
التخصصات الرئيسية
الملخص EN
The mass collision energy loss(dE/dX),themassradiative energy loss (Srad/) and the total mass stopping power of electrons in the energy range of 0.01 MeV up to 1000 MeV has been calculated for Lung, Urea and Skin.
The results of the present work for the mass collision stopping power of electrons in Lung, Urea and Skin are in excellent agreement with the standard results given by ESTAR program, where the maximum percentage error between the present calculated values and that of ESTAR program in Lung tissue, Urea and Skin tissue is 0.27%, 0.3%and 0.8%respectively.
The mass radiative energy loss of electrons in the same energy range is also calculated using a modified equation, andthe results are found to be in very good agreement with the standard published values.
The employed modified equation used to calculatethe mass radiative energy loss of electronsis valid in the energy range of electrons from 0.01 MeV up to 1000 MeV and gives accurate results.
As the results of total stopping power calculation are concerned, they are found in excellent agreement with the published results, where the error is less than 1%.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Kamun, Said Salman& Mahdi, Janan Fadil. 2017. Calculation of the total mass stopping power for electrons in some human body tissues in the energy range 0.01-1000 MeV. Iraqi Journal of Physics،Vol. 15, no. 34, pp.72-80.
https://search.emarefa.net/detail/BIM-754733
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Kamun, Said Salman& Mahdi, Janan Fadil. Calculation of the total mass stopping power for electrons in some human body tissues in the energy range 0.01-1000 MeV. Iraqi Journal of Physics Vol. 15, no. 34 (2017), pp.72-80.
https://search.emarefa.net/detail/BIM-754733
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Kamun, Said Salman& Mahdi, Janan Fadil. Calculation of the total mass stopping power for electrons in some human body tissues in the energy range 0.01-1000 MeV. Iraqi Journal of Physics. 2017. Vol. 15, no. 34, pp.72-80.
https://search.emarefa.net/detail/BIM-754733
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references : p. 80
رقم السجل
BIM-754733
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر