Accuracy assessment of analytical orientation process in close range photogrammetry

المؤلفون المشاركون

al-Hassun, Farah Sad A.
Muhammad, Nisrin S.
Khalaf, Abbas Zaydan

المصدر

Engineering and Technology Journal

العدد

المجلد 34، العدد 14A (31 ديسمبر/كانون الأول 2016)، ص ص. 2739-2753، 15ص.

الناشر

الجامعة التكنولوجية

تاريخ النشر

2016-12-31

دولة النشر

العراق

عدد الصفحات

15

التخصصات الرئيسية

العلوم الهندسية والتكنولوجية (متداخلة التخصصات)

الملخص EN

This paper studies data manipulation using analytical relative orientation process to determine the exterior orientation parameters.

This process can be accomplished by two scenarios; the first one is implemented using collinearity condition while the second one is implemented using coplanarity condition.

The final results of both scenarios will be a three dimensional (3D) model and in order to specify the more precise scenario in reconstruction of (3D) models Root Mean Square Error (RMSE) for each scenario was computed.

Absolute orientation process was used to transform coordinates of the model system into coordinates of the ground system then (RMSE) for each was computed.

The difficulty of obtaining Ground Control Points (GCPs) that covers the photogrammetric project had been overcome by establishing a Portable Control System (PCS) .This (PCS) is a block made of an Aluminum alloy that had been shaped by a (TNC) milling machine to produce plane surfaces on it.

The points of intersection of the produced surfaces on the block was labeled or coded and the distances between these points were measured manually by the digital vernier caliper 150mm and micrometer.

These points represented control points in the captured images also a specific point within the block was chosen to be the center of this control system and all the remaining points was calculated with reference to it.

The calculated (RMSE) for collinearity condition was 1.0212 mm.

while for coplanarity condition was 1.0230 mm.

So the precision of both models is nearly identical moreover coplanarity condition was more feasible for the requirements of close range photogrammetry

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Khalaf, Abbas Zaydan& Muhammad, Nisrin S.& al-Hassun, Farah Sad A.. 2016. Accuracy assessment of analytical orientation process in close range photogrammetry. Engineering and Technology Journal،Vol. 34, no. 14A, pp.2739-2753.
https://search.emarefa.net/detail/BIM-756224

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Khalaf, Abbas Zaydan…[et al.]. Accuracy assessment of analytical orientation process in close range photogrammetry. Engineering and Technology Journal Vol. 34, no. 14A (2016), pp.2739-2753.
https://search.emarefa.net/detail/BIM-756224

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Khalaf, Abbas Zaydan& Muhammad, Nisrin S.& al-Hassun, Farah Sad A.. Accuracy assessment of analytical orientation process in close range photogrammetry. Engineering and Technology Journal. 2016. Vol. 34, no. 14A, pp.2739-2753.
https://search.emarefa.net/detail/BIM-756224

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references : p. 2752-2753

رقم السجل

BIM-756224