The effect of treatment protocol and implant dimensions on primary stability utilizing resonance frequency analysis

المؤلف

Abd al-Laif, Thair

المصدر

Journal of Baghdad College of Dentistry

العدد

المجلد 29، العدد 1 (31 مارس/آذار 2017)، ص ص. 111-116، 6ص.

الناشر

جامعة بغداد كلية طب الأسنان

تاريخ النشر

2017-03-31

دولة النشر

العراق

عدد الصفحات

6

التخصصات الرئيسية

طب الأسنان
الطب البشري

الموضوعات

الملخص EN

Background : according to Branemark’s protocol, the waiting period between tooth extraction and implant placement is 6–8 months; this is the late placement technique.

Achieving and maintaining implant stability are prerequisites for a dental implant to be successful.

Resonance Frequency Analysis (RFA) is a noninvasive diagnostic method that measures implant stability.

The aim of this study was to investigate the influence of treatment protocol and implant dimensions on primary implant stability utilizing RFA.

Materials and methods : this study included 63 Iraqi patients (37 male, 26 female; ranging 22-66 years).

According to treatment protocol, the sample was divided into 2 groups; A (delayed) and B (immediate).

Dental implants were inserted and the implant stability quotient (ISQ) measures for primary stability documented by Osstell device.

Results : for both groups fixtures introduced in the mandible showed a higher stability (74 and 71.85) respectively and was lower in maxilla.

The mean primary stability of group A was 70.21 (ranged from 51-83), while for group B was 68.55 (46.5-81).

Conclusion : primary stability influencing osseointegration and subsequent long term success.

It was higher in association with delayed implant placement, mandible, and increased implant diameters.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Abd al-Laif, Thair. 2017. The effect of treatment protocol and implant dimensions on primary stability utilizing resonance frequency analysis. Journal of Baghdad College of Dentistry،Vol. 29, no. 1, pp.111-116.
https://search.emarefa.net/detail/BIM-770002

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Abd al-Laif, Thair. The effect of treatment protocol and implant dimensions on primary stability utilizing resonance frequency analysis. Journal of Baghdad College of Dentistry Vol. 29, no. 1 (Mar. 2017), pp.111-116.
https://search.emarefa.net/detail/BIM-770002

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Abd al-Laif, Thair. The effect of treatment protocol and implant dimensions on primary stability utilizing resonance frequency analysis. Journal of Baghdad College of Dentistry. 2017. Vol. 29, no. 1, pp.111-116.
https://search.emarefa.net/detail/BIM-770002

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references : p. 116

رقم السجل

BIM-770002