Evaluation of equivalent stiffness and maximum axial load of M2-panel system walls

المؤلف

Hilal, A. M.

المصدر

Journal of al Azhar University : Engineering Sector

العدد

المجلد 11، العدد 38 (31 يناير/كانون الثاني 2016)، ص ص. 265-273، 9ص.

الناشر

جامعة الأزهر كلية الهندسة

تاريخ النشر

2016-01-31

دولة النشر

مصر

عدد الصفحات

9

التخصصات الرئيسية

العلوم الهندسية والتكنولوجية (متداخلة التخصصات)

الملخص EN

A new construction method depending on composite panels composed of a Polystyrene corrugated layer surrounded by two concrete layers is tested to prove its effectiveness as wall bearing panels.

3 different full scale specimen 1000mm wide and 3000mm high were fabricated and tested under centric axial load.

The tested variables were the thickness of concrete layers surrounding the foam layer and the method of concrete application.

Thicknesses of 30 and 35 mm were used and wet shot-crete vs.

manual concrete application were evaluated.

Test results were analyzed to assess the maximum safe axial load that could be carried by this type of wall, also the equivalent effective stiffness for the walls according to load-lateral deformation behavior was dedicated.

Results showed the higher the concrete thickness was, the more load it carried, also showed an increase of axial load capacity for the wet shot-crete method of concrete application over the manual concrete application

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Hilal, A. M.. 2016. Evaluation of equivalent stiffness and maximum axial load of M2-panel system walls. Journal of al Azhar University : Engineering Sector،Vol. 11, no. 38, pp.265-273.
https://search.emarefa.net/detail/BIM-855645

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Hilal, A. M.. Evaluation of equivalent stiffness and maximum axial load of M2-panel system walls. Journal of al Azhar University : Engineering Sector Vol. 11, no. 38 (Jan. 2016), pp.265-273.
https://search.emarefa.net/detail/BIM-855645

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Hilal, A. M.. Evaluation of equivalent stiffness and maximum axial load of M2-panel system walls. Journal of al Azhar University : Engineering Sector. 2016. Vol. 11, no. 38, pp.265-273.
https://search.emarefa.net/detail/BIM-855645

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

رقم السجل

BIM-855645