Percutaneous carillon mitral contour system deployment followed by CRT-d implantation : first case report from Oman
المؤلفون المشاركون
al-Said, Ahmad Muhammad
Chase, David
al-Rawahi, Najib Zahran
المصدر
العدد
المجلد 33، العدد 6 (30 نوفمبر/تشرين الثاني 2018)، ص ص. 531-534، 4ص.
الناشر
المجلس العماني للاختصاصات الطبية
تاريخ النشر
2018-11-30
دولة النشر
سلطنة عمان
عدد الصفحات
4
التخصصات الرئيسية
الملخص EN
Mitral valve regurgitation (MR) is a common problem in patients with cardiac issues especially those with dilated cardiomyopathy (DCM) due to mitral annular dilatation and malcoaptation of the mitral valve leaflets.
Although DCM is associated with high mortality rates, there has been no global agreement about the best method of treatment.
Treatment of MR in such cases can be done by surgery, which has many limitations due to high-risk concerns.
MR may also be managed by other alternatives such as mitral-clip and transcoronary venous mitral annuloplasty using the Carillon® Mitral Contour System®.
Combined therapy with a cardiac resynchronization therapy defibrillator (CRT-D) and mitral contour can be used in such cases with valuable improvement in general condition in many patients.
In our case, we used the Carillon Mitral Contour System for treatment of severe MR in a 64-year-old patient with severely impaired systolic function after implantation of a CRT-D.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
al-Said, Ahmad Muhammad& al-Rawahi, Najib Zahran& Chase, David. 2018. Percutaneous carillon mitral contour system deployment followed by CRT-d implantation : first case report from Oman. Oman Medical Journal،Vol. 33, no. 6, pp.531-534.
https://search.emarefa.net/detail/BIM-880708
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
al-Said, Ahmad Muhammad…[et al.]. Percutaneous carillon mitral contour system deployment followed by CRT-d implantation : first case report from Oman. Oman Medical Journal Vol. 33, no. 6 (Nov. 2018), pp.531-534.
https://search.emarefa.net/detail/BIM-880708
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
al-Said, Ahmad Muhammad& al-Rawahi, Najib Zahran& Chase, David. Percutaneous carillon mitral contour system deployment followed by CRT-d implantation : first case report from Oman. Oman Medical Journal. 2018. Vol. 33, no. 6, pp.531-534.
https://search.emarefa.net/detail/BIM-880708
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references : p. 534
رقم السجل
BIM-880708
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر