Evaluation of low GWP refrigerants as alternatives for R134a in a vapor compression refrigeration cycle under varying operating conditions

المؤلفون المشاركون

Ways, Musa Mustafa
Abd al-Amir, Qusayy Rashid

المصدر

Journal of University of Babylon for Engineering Sciences

العدد

المجلد 25، العدد 1 (28 فبراير/شباط 2017)، ص ص. 346-359، 14ص.

الناشر

جامعة بابل

تاريخ النشر

2017-02-28

دولة النشر

العراق

عدد الصفحات

14

التخصصات الرئيسية

الهندسة الميكانيكية

الملخص EN

The present work is a numerical comparative study for low GWP refrigerants based on R161, R152a, R1234ze(e) and R1234yf as a substitute for R134a in a vapor compression refrigeration cycle under varying operating conditions.

A computational model is developed by engineering equation solver software (EES).

The effects of degree of subcooling, superheating, evaporating and condensing temperatures on the main performance parameters in term of mass flow rate of refrigerant, pressure ratio, volumetric cooling capacity, compressor input power and coefficient of performance are computed for selected refrigerants.

The performance results are compared with respect to R134a.

The results indicated that the coefficient of performance for R152a is slightly better than the other refrigerants under various operating conditions.

The refrigerant R1234ze(e) has approximately the same COP and VCC of R134a and it has the lowest compressor input power and TEWI value over the four compared low GWP refrigerants.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Abd al-Amir, Qusayy Rashid& Ways, Musa Mustafa. 2017. Evaluation of low GWP refrigerants as alternatives for R134a in a vapor compression refrigeration cycle under varying operating conditions. Journal of University of Babylon for Engineering Sciences،Vol. 25, no. 1, pp.346-359.
https://search.emarefa.net/detail/BIM-918367

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Abd al-Amir, Qusayy Rashid& Ways, Musa Mustafa. Evaluation of low GWP refrigerants as alternatives for R134a in a vapor compression refrigeration cycle under varying operating conditions. Journal of University of Babylon for Engineering Sciences Vol. 25, no. 1 (2017), pp.346-359.
https://search.emarefa.net/detail/BIM-918367

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Abd al-Amir, Qusayy Rashid& Ways, Musa Mustafa. Evaluation of low GWP refrigerants as alternatives for R134a in a vapor compression refrigeration cycle under varying operating conditions. Journal of University of Babylon for Engineering Sciences. 2017. Vol. 25, no. 1, pp.346-359.
https://search.emarefa.net/detail/BIM-918367

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes appendices : p. 357-359

رقم السجل

BIM-918367