Experimental investigation of the effect of hot finnedtube position on the heat transfer coefficient

المؤلفون المشاركون

Siddiq, Murad S.
Wais, Musa M.
Abbas, Ihsan Fadil

المصدر

Journal of University of Babylon for Engineering Sciences

العدد

المجلد 25، العدد 2 (30 إبريل/نيسان 2017)، ص ص. 685-692، 8ص.

الناشر

جامعة بابل

تاريخ النشر

2017-04-30

دولة النشر

العراق

عدد الصفحات

8

التخصصات الرئيسية

الهندسة الميكانيكية

الملخص EN

In the present study, an experimental investigation is carried out to calculate heat transfer coefficient from the change in position of a finned tube in the cross-flow heat exchanger in two different conditions, which are a constant temperature at 90oC and constant heat flux at 45W/m2.

A standard laboratory device (crossflow heat exchanger) was used in experiment process, that which manufactured by EDIBON company.

The air flow over finned tubes inside heat exchanger was studied at Reynolds number ranging from 3600 to 11600.

The comparative of experiments results between two cases shows that the Nu number in four positions at the constant temperature condition are higher than symmetrical positions in constant heat flux.

The results indicated that the position3 gives higher values of Nu number in both cases.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Abbas, Ihsan Fadil& Siddiq, Murad S.& Wais, Musa M.. 2017. Experimental investigation of the effect of hot finnedtube position on the heat transfer coefficient. Journal of University of Babylon for Engineering Sciences،Vol. 25, no. 2, pp.685-692.
https://search.emarefa.net/detail/BIM-923392

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Abbas, Ihsan Fadil…[et al.]. Experimental investigation of the effect of hot finnedtube position on the heat transfer coefficient. Journal of University of Babylon for Engineering Sciences Vol. 25, no. 2 (2017), pp.685-692.
https://search.emarefa.net/detail/BIM-923392

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Abbas, Ihsan Fadil& Siddiq, Murad S.& Wais, Musa M.. Experimental investigation of the effect of hot finnedtube position on the heat transfer coefficient. Journal of University of Babylon for Engineering Sciences. 2017. Vol. 25, no. 2, pp.685-692.
https://search.emarefa.net/detail/BIM-923392

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references : p. 691-692

رقم السجل

BIM-923392