A comparison between high ablative versus usual dosages of iodine-131 in inducing hypothyroidism after one year of therapy in hyperthyroid patients

المؤلف

Fulayyih, Thamir S.

المصدر

al-Kindy College Medical Journal

العدد

المجلد 15، العدد 2 (31 ديسمبر/كانون الأول 2019)، ص ص. 18-22، 5ص.

الناشر

جامعة بغداد كلية الطب الكندي

تاريخ النشر

2019-12-31

دولة النشر

العراق

عدد الصفحات

5

التخصصات الرئيسية

الطب البشري

الملخص EN

Background: Radioactive iodine-131 therapy is highly effective in treating patients with hyperthyroidism.

An ablative dose is preferred by a number of endocrinologists, and, a fixed dose protocol seems to be better than a calculated dose in real practice.

Objective: To check for hypothyroidism in hyperthyroid patients one year after RAI therapy, comparing between the results of high ablative versus usual dosages of RAI-131.

Methods: This study included 174 hyperthyroid patients, 101 males and 73 females, divided into 2 groups, the first consisted of 162 patients given a usual fixed dose of RAI while the second consisted of 12 patients given a high fixed ablative dose of RAI.

The study lasted about 2 years from August 2000 till July 2002 in the Specialized Centre for Endocrinology & Diabetes, Baghdad.

Results: Out of 162 patients in the first group, 11 patients (6.8%), developed hypothyroidism compared to 4 patients out of 12 (33.3% ) in the second group ( p < 0.05).

Conclusion: A high ablative dose RAI has a better outcome regarding hypothyroidism than a usual dose, although, endocrinologists have different opinions regarding this issue.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Fulayyih, Thamir S.. 2019. A comparison between high ablative versus usual dosages of iodine-131 in inducing hypothyroidism after one year of therapy in hyperthyroid patients. al-Kindy College Medical Journal،Vol. 15, no. 2, pp.18-22.
https://search.emarefa.net/detail/BIM-945800

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Fulayyih, Thamir S.. A comparison between high ablative versus usual dosages of iodine-131 in inducing hypothyroidism after one year of therapy in hyperthyroid patients. al-Kindy College Medical Journal Vol. 15, no. 2 (2019), pp.18-22.
https://search.emarefa.net/detail/BIM-945800

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Fulayyih, Thamir S.. A comparison between high ablative versus usual dosages of iodine-131 in inducing hypothyroidism after one year of therapy in hyperthyroid patients. al-Kindy College Medical Journal. 2019. Vol. 15, no. 2, pp.18-22.
https://search.emarefa.net/detail/BIM-945800

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references : p. 21-22

رقم السجل

BIM-945800