Performance assessment of first grid-tied PV solar system under Baghdad city climate condition
العناوين الأخرى
تقييم أداء أول منظومة شمسية كهروضوئية مربوطة على الشبكة الوطنية في ظل الظروف المناخية لمدينة بغداد
المؤلفون المشاركون
Ubayd, Nibras Mahmud
Qasim, Nusayr Karim
Hashim, Imad Talib
المصدر
Iraqi Journal of Science and Technology
العدد
المجلد 10، العدد 1 (30 إبريل/نيسان 2019)9ص.
الناشر
تاريخ النشر
2019-04-30
دولة النشر
العراق
عدد الصفحات
9
التخصصات الرئيسية
الملخص EN
The performance assessment of 15 kWp PV solar system installed at Baghdad/Iraq was achieved.
The yields (final, reference) and performance ratio where changeable from (3.5-4.8) kWh/kWp-day, (4.3-7) kWh/kWp-day and (66-83) %respectively.
The average yearly capacity factor was 18.4%, annual average performance ratio was75.55% with system efficiency of 13.27%, the yearly energy yield was 1585.16 kWh/kWp of year 2018.
By using PVsyst software, it was found that the yearly predicted energy yield 1631 kWh/kWp with uncertainty of 2.8% from real value, this was because of differences between real metrological date of rainy and cloudy days in winter season and hot weather in summer season and estimated data in PVsyst software.
The overall predict system losses due to module temperature rise, radiation reflection losses from the collector, system losses of inverter and DC, AC wiring were 16.7 %.
The present study showed the generated energy was at a high value in August and lowest in December.
The system performance was compared with other Grid-Tied PV solar systems in various countries around the world and found comparable.
itis proved the very good long-term performance of this solar system in real operation conditions in Baghdad city climate in spite of high temperature in summer days and cloudy and rainy days during winter in Baghdad city.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Ubayd, Nibras Mahmud& Qasim, Nusayr Karim& Hashim, Imad Talib. 2019. Performance assessment of first grid-tied PV solar system under Baghdad city climate condition. Iraqi Journal of Science and Technology،Vol. 10, no. 1.
https://search.emarefa.net/detail/BIM-972420
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Ubayd, Nibras Mahmud…[et al.]. Performance assessment of first grid-tied PV solar system under Baghdad city climate condition. Iraqi Journal of Science and Technology Vol. 10, no. 1 (2019).
https://search.emarefa.net/detail/BIM-972420
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Ubayd, Nibras Mahmud& Qasim, Nusayr Karim& Hashim, Imad Talib. Performance assessment of first grid-tied PV solar system under Baghdad city climate condition. Iraqi Journal of Science and Technology. 2019. Vol. 10, no. 1.
https://search.emarefa.net/detail/BIM-972420
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-972420
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر