In the current work, a thermosyphon was used to investigate the effect of condenser length on its performance.
Experimentally by using a pipe of copper having same evaporator length of 120 mm and three different condenser lengths which were 400 mm, 500 mm and 600 mm.
The internal and external diameters of the thermosyphon were 26 mm and 28 mm respectively.
The evaporator part of the thermosyphon was immersed in the electrical transformer oil, which heated by external heater from ambient temperature to approximately 80 oC, while the condenser part was left to cool naturally by air.
Five thermocouples were located on the thermosyphon wall to read the temperature distribution at different positions.
The working fluid was water with filling ratio of 50%.
The results have obviously shown that temperature gradient was decreased when the condenser length increased and giving a better performance for heat dissipation.
The percentage of temperature gradient was positively correlated to the condenser length and it was found that condenser length of ( 400, 500, 600) mm gave percentage of decreasing temperature gradient are 67.
94 %, 72.
94 %, and 77.
06 % respectively with respect to that without using thermosyphon.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Faraj, Talib Z.& al-Sakini, Sahar R.& Ismail, Asil A.. 2019. Experimental determination of condenser length effect on the thermosyphon performan. The Iraqi Journal for Mechanical and Materials Engineering،Vol. 19, no. 3, pp.287-294.
https://search.emarefa.net/detail/BIM-973904
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
al-Sakini, Sahar R.…[et al.]. Experimental determination of condenser length effect on the thermosyphon performan. The Iraqi Journal for Mechanical and Materials Engineering Vol. 19, no. 3 (Sep. 2019), pp.287-294.
https://search.emarefa.net/detail/BIM-973904
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Faraj, Talib Z.& al-Sakini, Sahar R.& Ismail, Asil A.. Experimental determination of condenser length effect on the thermosyphon performan. The Iraqi Journal for Mechanical and Materials Engineering. 2019. Vol. 19, no. 3, pp.287-294.
https://search.emarefa.net/detail/BIM-973904
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references : p. 293-294
رقم السجل
BIM-973904
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر