MODULAR ANALYTICS Serum Work Area (in USA Integrated MODULAR ANALYTICS, MODULAR ANALYTICS is a trademark of a member of the Roche Group) represents a further approach to automation in the laboratory medicine.
This instrument combines previously introduced modular systems for the clinical chemistry and immunochemistry laboratory and allows customised combinations for various laboratory workloads.
Functionality, practicability, and workflow behaviour of MODULAR ANALYTICS Serum Work Area were evaluated in an international multicenter study at six laboratories.
Across all experiments, 236000 results from 32400 samples were generated using 93 methods.
Simulated routine testing which included provocation incidents and anomalous situations demonstrated good performance and full functionality.
Heterogeneous immunoassays, performed on the E-module with the electrochemiluminescence technology, showed reproducibility at the same level of the general chemistry tests, which was well within the clinical demands.
Sample carryover cannot occur due to intelligent sample processing.
Workflow experiments for the various module combinations, with menus of about 50 assays, yielded mean sample processing times of <38 minutes for combined clinical chemistry and immunochemistry requests; <50 minutes including automatically repeated samples.
MODULAR ANALYTICS Serum Work Area offered simplified workflow by combining various laboratory segments.
It increased efficiency while maintaining or even improving quality of laboratory processes.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Mocarelli, Paolo& Horowitz, Gary L.& Gerthoux, Pier Mario& Cecere, Rossana& Imdahl, Roland& Ruinemans-Koerts, Janneke…[et al.]. 2008. Increasing Efficiency and Quality by Consolidation of Clinical Chemistry and Immunochemistry Systems with MODULAR ANALYTICS SWA. Journal of Analytical Methods in Chemistry،Vol. 2008, no. 2008, pp.1-14.
https://search.emarefa.net/detail/BIM-987964
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Mocarelli, Paolo…[et al.]. Increasing Efficiency and Quality by Consolidation of Clinical Chemistry and Immunochemistry Systems with MODULAR ANALYTICS SWA. Journal of Analytical Methods in Chemistry No. 2008 (2008), pp.1-14.
https://search.emarefa.net/detail/BIM-987964
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Mocarelli, Paolo& Horowitz, Gary L.& Gerthoux, Pier Mario& Cecere, Rossana& Imdahl, Roland& Ruinemans-Koerts, Janneke…[et al.]. Increasing Efficiency and Quality by Consolidation of Clinical Chemistry and Immunochemistry Systems with MODULAR ANALYTICS SWA. Journal of Analytical Methods in Chemistry. 2008. Vol. 2008, no. 2008, pp.1-14.
https://search.emarefa.net/detail/BIM-987964
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-987964
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر