![](/images/graphics-bg.png)
Hydraulic performance for combined weir-gate structure
Other Title(s)
الأداء الهيدروليكي لمنشأ مكون من بوابة و هدار
Parallel Title
الأداء الهيدروليكي لمنشأ مكون من بوابة و هدار
Joint Authors
Jalil, Shakir Abd al-Latif
Husayn, Bshkoj Sidqi
Source
Tikrit Journal of Engineering Sciences
Issue
Vol. 27, Issue 1 (31 Mar. 2020), pp.40-50, 11 p.
Publisher
Tikrit University Colleg of Engineering
Publication Date
2020-03-31
Country of Publication
Iraq
No. of Pages
11
Main Subjects
Topics
Abstract AR
تلعب المنشآت الهیدرولیكیة ذات الهدار و البوابة دو را مهما في التحكم بالتصرف في القنوات المفتوحة.
استندت هذه الدراسة إلى التجارب العملیة و النمذجةالعددية للجريان المشترك المار خالل هذه المنشآت الهیدرولیكیة.
لهذه الغاية تم استخدام ثالثة نماذج للهدار شبه منحرف حاد الحافة و كل هدار يحتوى علىفتحة بوابة في االسفل.
كانت البوابات مختلفة االشكال فاالولى مستطیلة أما البوابة الثانیة و الثالثة فكانتا على شكل شبه منحرف يختلف میل جوانبهما 2V: 1Hواالخرى 4V: 1H كما تم اختبار هدار شبه منحرف بدون بوابة.
تم اختبار النماذج االربعة عن طريق تمرير ثمانیة تصاريف مختلفة على كل نموذج.
تمقیاس منسوب السطح الحر للماء على مسافات متقاربة لتحديد شكل السطح للماء المتكون لكل جريان وقد اتضح بان منسوب الماء يستقرعلى بعد 11h.2 منحافة الهدار.
وتم استخدام برنامج الدينامیكا للموائع التجاري CFX ANSYS لمحاكاة التدفق عدديا لتفسیر ظاهرة الجريان.
استند التحقق من مخرجاتالنموذج العددي على شكل سطح الماء و قیمة التصريف اللتین أظهرتا اتفاقا مقبوال وأن قیمة معامل التصريف Cd تتراوح بین )52.0-58.0.
)وقد اتضحأيضا بأن كال النموذجین ذاتا البوابة شبه المنحرفة تستطیع امرار تصريف أعلى من النموذج مع بوابة مستطیلة بمتوسط نسبة زيادة في التصريف )78.40٪ و 40.19 )٪ لكل من الهدارات ذات الفتحة شبه المنحرفة بمیل جوانب (2V: 1H(و(4V: 1H (على التوالى.
إضافة إلى ذلك فإن نظام الهدارات المركبةالذي يكون فیه میل البوابة الجانبي صغی را لديه قدرة على تصريف كمیة أكبر و أداء أفضل بنسبة 40 ٪بالمقارنة مع االنواع التقلیدية.
أخی را تم استنباطمعادالت و ضعیة لتقدير قیمة معامالت التصريف لجمیع النماذج.
Abstract EN
Combined hydraulic structure play an important role in controlling flow in open channels.
This study was based on experimental and numerical modeling investigations for combined hydraulic structure.
For this purpose three physical models of combined sharp crested trapezoidal weir with bottom opening and one physical model of sharpcrested trapezoidal weir separately were used and tested by running eight different flow rates over each model.
In which three configurations of bottom opening were tested; the first configuration is a rectangular gate while other two configuration were trapezoidal with two different side slopes of (1V: 4H) and (1V: 2H).
The water surface profiles passing through weir-gate system were measured for all thirty two runs of all models which show uniform flow at 2.11h from the upstream of weir.
The commercialcomputational fluid dynamic software ANSYS CFX was used to simulate flow numerically.
The verification of the numerical model was based on water surface profiles and discharge which showed acceptable agreement.
Also, the results showed that discharge coefficient Cd varies from (0.52-0.58).
Furthermore, it was shown that bothmodels with trapezoidal gate pass a higher discharge of flow than the model with rectangular gate with average percentage increase of discharge (40.78% and 19.40% ) for trapezoidal side slopes (1H: 2V and 1H: 4V) respectively.
In addition, the combined system with milder trapezoidal side slopes of bottom opening had a better performancefor discharging weir flow which is about 40% as compared with traditional one.
Finally, the empirical equations for stage-discharge relationship were estimated for all models and discharge coefficients were estimated for all runs.
American Psychological Association (APA)
Husayn, Bshkoj Sidqi& Jalil, Shakir Abd al-Latif. 2020. Hydraulic performance for combined weir-gate structure. Tikrit Journal of Engineering Sciences،Vol. 27, no. 1, pp.40-50.
https://search.emarefa.net/detail/BIM-1004192
Modern Language Association (MLA)
Husayn, Bshkoj Sidqi& Jalil, Shakir Abd al-Latif. Hydraulic performance for combined weir-gate structure. Tikrit Journal of Engineering Sciences Vol. 27, no. 1 (2020), pp.40-50.
https://search.emarefa.net/detail/BIM-1004192
American Medical Association (AMA)
Husayn, Bshkoj Sidqi& Jalil, Shakir Abd al-Latif. Hydraulic performance for combined weir-gate structure. Tikrit Journal of Engineering Sciences. 2020. Vol. 27, no. 1, pp.40-50.
https://search.emarefa.net/detail/BIM-1004192
Data Type
Journal Articles
Language
English
Notes
-
Record ID
BIM-1004192