Calculation Formula Optimization and Effect of Ring Clearance on Axial Force of Multistage Pump

Joint Authors

Wang, Chuan
Shi, Weidong
Zhang, Li

Source

Mathematical Problems in Engineering

Issue

Vol. 2013, Issue 2013 (31 Dec. 2013), pp.1-7, 7 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2013-10-24

Country of Publication

Egypt

No. of Pages

7

Main Subjects

Civil Engineering

Abstract EN

Since overlarge axial force can damage the pump, accurate calculation formula of axial force on pump is very significant.

The traditional formula is based on the assumption that the leakage amount of the pump is zero and the angular speed of fluid in the pump chamber rotates at half the impeller rotation’s angular speed.

In order to propose an accurate calculation formula, the whole flow fields of multistage pumps with three different ring clearances were calculated by using Computational Fluid Dynamics (CFD).

The results indicate that the axial force on first-stage impeller is larger than that on the second.

Along with the change of ring clearance, the static pressure distribution on the shroud of impeller changes at the same time, which leads to the value change of axial force.

Meanwhile, angular speed of the fluid in the pump chamber is changing.

Therefore, this research works out the reason why the error of traditional axial force calculation is large when the amount of leakage is relatively high.

At last, an accurate calculation formula of axial force on pump is obtained through the verification of numerical simulation and experiment.

American Psychological Association (APA)

Wang, Chuan& Shi, Weidong& Zhang, Li. 2013. Calculation Formula Optimization and Effect of Ring Clearance on Axial Force of Multistage Pump. Mathematical Problems in Engineering،Vol. 2013, no. 2013, pp.1-7.
https://search.emarefa.net/detail/BIM-1010598

Modern Language Association (MLA)

Wang, Chuan…[et al.]. Calculation Formula Optimization and Effect of Ring Clearance on Axial Force of Multistage Pump. Mathematical Problems in Engineering No. 2013 (2013), pp.1-7.
https://search.emarefa.net/detail/BIM-1010598

American Medical Association (AMA)

Wang, Chuan& Shi, Weidong& Zhang, Li. Calculation Formula Optimization and Effect of Ring Clearance on Axial Force of Multistage Pump. Mathematical Problems in Engineering. 2013. Vol. 2013, no. 2013, pp.1-7.
https://search.emarefa.net/detail/BIM-1010598

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1010598