Entanglement due to Delayed Removal of a Buddy Wire

Joint Authors

Vorpahl, Marc
Seyfarth, Melchior
Tiroch, Klaus

Source

Case Reports in Cardiology

Issue

Vol. 2014, Issue 2014 (31 Dec. 2014), pp.1-3, 3 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2014-12-29

Country of Publication

Egypt

No. of Pages

3

Main Subjects

Diseases

Abstract EN

A buddy wire is often used to aid in the delivery of balloons and stents when negotiating tortuous or calcified vessels.

We present a planned two-stent mini-crush intervention complicated by entanglement of the buddy wire with the second stent and subsequent distortion of the stent within the guiding catheter.

Based on this case, we suggest removing the buddy wire immediately after successful positioning of the first stent, because entrapment with a second stent is possible and may lead to challenging situations in a simultaneous two-stent strategy.

American Psychological Association (APA)

Vorpahl, Marc& Seyfarth, Melchior& Tiroch, Klaus. 2014. Entanglement due to Delayed Removal of a Buddy Wire. Case Reports in Cardiology،Vol. 2014, no. 2014, pp.1-3.
https://search.emarefa.net/detail/BIM-1016869

Modern Language Association (MLA)

Vorpahl, Marc…[et al.]. Entanglement due to Delayed Removal of a Buddy Wire. Case Reports in Cardiology No. 2014 (2014), pp.1-3.
https://search.emarefa.net/detail/BIM-1016869

American Medical Association (AMA)

Vorpahl, Marc& Seyfarth, Melchior& Tiroch, Klaus. Entanglement due to Delayed Removal of a Buddy Wire. Case Reports in Cardiology. 2014. Vol. 2014, no. 2014, pp.1-3.
https://search.emarefa.net/detail/BIM-1016869

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1016869