![](/images/graphics-bg.png)
Similar-Case-Based Optimization of Beam Arrangements in Stereotactic Body Radiotherapy for Assisting Treatment Planners
Joint Authors
Shioyama, Yoshiyuki
Honda, Hiroshi
Magome, Taiki
Hirata, Hideki
Nakamura, Katsumasa
Arimura, Hidetaka
Source
Issue
Vol. 2013, Issue 2013 (31 Dec. 2013), pp.1-10, 10 p.
Publisher
Hindawi Publishing Corporation
Publication Date
2013-11-02
Country of Publication
Egypt
No. of Pages
10
Main Subjects
Abstract EN
Objective.
To develop a similar-case-based optimization method for beam arrangements in lung stereotactic body radiotherapy (SBRT) to assist treatment planners.
Methods.
First, cases that are similar to an objective case were automatically selected based on geometrical features related to a planning target volume (PTV) location, PTV shape, lung size, and spinal cord position.
Second, initial beam arrangements were determined by registration of similar cases with the objective case using a linear registration technique.
Finally, beam directions of the objective case were locally optimized based on the cost function, which takes into account the radiation absorption in normal tissues and organs at risk.
The proposed method was evaluated with 10 test cases and a treatment planning database including 81 cases, by using 11 planning evaluation indices such as tumor control probability and normal tissue complication probability (NTCP).
Results.
The procedure for the local optimization of beam arrangements improved the quality of treatment plans with significant differences (P<0.05) in the homogeneity index and conformity index for the PTV, V10, V20, mean dose, and NTCP for the lung.
Conclusion.
The proposed method could be usable as a computer-aided treatment planning tool for the determination of beam arrangements in SBRT.
American Psychological Association (APA)
Magome, Taiki& Arimura, Hidetaka& Shioyama, Yoshiyuki& Nakamura, Katsumasa& Honda, Hiroshi& Hirata, Hideki. 2013. Similar-Case-Based Optimization of Beam Arrangements in Stereotactic Body Radiotherapy for Assisting Treatment Planners. BioMed Research International،Vol. 2013, no. 2013, pp.1-10.
https://search.emarefa.net/detail/BIM-1030351
Modern Language Association (MLA)
Magome, Taiki…[et al.]. Similar-Case-Based Optimization of Beam Arrangements in Stereotactic Body Radiotherapy for Assisting Treatment Planners. BioMed Research International No. 2013 (2013), pp.1-10.
https://search.emarefa.net/detail/BIM-1030351
American Medical Association (AMA)
Magome, Taiki& Arimura, Hidetaka& Shioyama, Yoshiyuki& Nakamura, Katsumasa& Honda, Hiroshi& Hirata, Hideki. Similar-Case-Based Optimization of Beam Arrangements in Stereotactic Body Radiotherapy for Assisting Treatment Planners. BioMed Research International. 2013. Vol. 2013, no. 2013, pp.1-10.
https://search.emarefa.net/detail/BIM-1030351
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID