Abstract EN

This paper reports numerical investigations of heat transfer and friction factor characteristics in swirling flow conditions using CFD simulation.

A commercial CFD package, FLUENT 6.3.26, was used in this study.

3D models for circular tube fitted with classical and quadrant-cut twisted tape (QCT) inserts with three twist ratios (y = 2.93, 3.91, and 4.89) and different cut depths (w = 0.5, 1.0, and 1.5 cm) were generated for the simulation.

The data obtained from the CFD simulation were verified with the literature correlations of plain tube with the discrepancy of less than ±8% for Nusselt number and ±10% for friction factor.

The results show that there was a significant increase in heat transfer coefficient and friction factor in the tube fitted with quadrant-cut twisted tape (QCT) with decreasing of twist ratio (y) and cut depth (w).

Furthermore, the configuration of QCT insert with a twist ratio of y = 2.93 and a cut depth of w = 0.5 cm offered higher heat transfer rate and friction factor than other twist ratios.

American Psychological Association (APA)

Salman, Sami D.& Kadhum, Abdul Amir H.& Takriff, Mohd S.& Mohamad, Abu Bakar. 2013. CFD Analysis of Heat Transfer and Friction Factor Characteristics in a Circular Tube Fitted with Quadrant-Cut Twisted Tape Inserts. Mathematical Problems in Engineering،Vol. 2013, no. 2013, pp.1-8.
https://search.emarefa.net/detail/BIM-1031773

Modern Language Association (MLA)

Salman, Sami D.…[et al.]. CFD Analysis of Heat Transfer and Friction Factor Characteristics in a Circular Tube Fitted with Quadrant-Cut Twisted Tape Inserts. Mathematical Problems in Engineering No. 2013 (2013), pp.1-8.
https://search.emarefa.net/detail/BIM-1031773

American Medical Association (AMA)

Salman, Sami D.& Kadhum, Abdul Amir H.& Takriff, Mohd S.& Mohamad, Abu Bakar. CFD Analysis of Heat Transfer and Friction Factor Characteristics in a Circular Tube Fitted with Quadrant-Cut Twisted Tape Inserts. Mathematical Problems in Engineering. 2013. Vol. 2013, no. 2013, pp.1-8.
https://search.emarefa.net/detail/BIM-1031773

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1031773