Coating of Mesh Grafts for Prolapse and Urinary Incontinence Repair with Autologous Plasma: Exploration Stage of a Surgical Innovation

Joint Authors

Georgas, Evangelos
Gerullis, Holger
Barski, Dimitri
Ysebaert, Dirk
Otto, Thomas
Bär, Andreas
Lammers, Bernhard
Boros, Mihaly
Ramon, Albert
Klosterhalfen, Bernd

Source

BioMed Research International

Issue

Vol. 2014, Issue 2014 (31 Dec. 2014), pp.1-7, 7 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2014-09-16

Country of Publication

Egypt

No. of Pages

7

Main Subjects

Medicine

Abstract EN

Purpose.

Optimized biocompatibility is a major requirement for alloplastic materials currently applied for stress urinary incontinence (SUI) and pelvic organ prolapse (POP) repair.

In the preliminary studies the mesh modification by coating with autologous plasma resulted in the increased adherence score in vitro and improved biocompatibility in an animal model.

The first use of plasma coated meshes in human is presented.

Materials and Methods.

Between 04/2013 and 05/2014, 20 patients with the indication for SUI and POP repair were selected in a single institution.

The applied meshes were modified by autologous plasma coating prior to implantation.

A retrospective chart review for peri- and early postoperative complications was performed.

Functional outcome and QoL were evaluated pre- and postoperatively.

Results.

The functional outcome and QoL improved significantly in all groups.

Two reoperations (Grade IIIB) with the release of TVT-mesh in anesthesia due to the obstruction were needed.

No other severe complications were registered.

Conclusion.

For the first time we applied a mesh modification in a human setting according to IDEAL criteria of surgical innovations.

The procedure of mesh coating with autologous plasma is safe and a prospective randomized trial proving a positive effect of plasma coating on the biocompatibility and morbidity outcome with long-term registry is planned.

American Psychological Association (APA)

Barski, Dimitri& Gerullis, Holger& Georgas, Evangelos& Bär, Andreas& Lammers, Bernhard& Ramon, Albert…[et al.]. 2014. Coating of Mesh Grafts for Prolapse and Urinary Incontinence Repair with Autologous Plasma: Exploration Stage of a Surgical Innovation. BioMed Research International،Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-1034424

Modern Language Association (MLA)

Barski, Dimitri…[et al.]. Coating of Mesh Grafts for Prolapse and Urinary Incontinence Repair with Autologous Plasma: Exploration Stage of a Surgical Innovation. BioMed Research International No. 2014 (2014), pp.1-7.
https://search.emarefa.net/detail/BIM-1034424

American Medical Association (AMA)

Barski, Dimitri& Gerullis, Holger& Georgas, Evangelos& Bär, Andreas& Lammers, Bernhard& Ramon, Albert…[et al.]. Coating of Mesh Grafts for Prolapse and Urinary Incontinence Repair with Autologous Plasma: Exploration Stage of a Surgical Innovation. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-1034424

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1034424