Push-out tests for determining shear strength and stiffness of perfobond connector-experimental study

Joint Authors

Farhan, Khawlah A.
Shallal, Muhannad A.

Source

al-Qadisiyah Journal for Engineering Sciences

Issue

Vol. 12, Issue 4 (31 Dec. 2019), pp.225-231, 7 p.

Publisher

al-Qadisiyah University College of Engineering

Publication Date

2019-12-31

Country of Publication

Iraq

No. of Pages

7

Main Subjects

Civil Engineering

Topics

Abstract EN

This study presents an experimental investigation for push-out tests in order to evaluate the performance of continuous perfobond connectors.

A total of five specimens composed of light-weight concrete-filled steel tubes (square and circle sections) with two reinforced blocks were tested.

The measured parameters are the compressive strength of the concrete blocks and the type of the section.

The specimens were tested under a concentric load applied on the steel tube filled with lightweight concrete; the corresponding slip value was measured using two LVDTs.

The experimental results showed that the ultimate shear strength and stiffness of the square steel tube filled with concrete were higher than that of circular samples.

The ultimate shear strength and stiffness increased with an increase of concrete compressive strength, while the corresponding slips showed decreasing in their values with increase of the compressive strength of the This study presents an experimental investigation for push-out tests in order to evaluate the performance of continuous perfobond connectors.

A total of five specimens composed of light-weight concrete-filled steel tubes (square and circle sections) with two reinforced blocks were tested.

The measured parameters are the compressive strength of the concrete blocks and the type of the section.

The specimens were tested under a concentric load applied on the steel tube filled with lightweight concrete; the corresponding slip value was measured using two LVDTs.

The experimental results showed that the ultimate shear strength and stiffness of the square steel tube filled with concrete were higher than that of circular samples.

The ultimate shear strength and stiffness increased with an increase of concrete compressive strength, while the corresponding slips showed decreasing in their values with increase of the compressive strength of the concrete.

American Psychological Association (APA)

Farhan, Khawlah A.& Shallal, Muhannad A.. 2019. Push-out tests for determining shear strength and stiffness of perfobond connector-experimental study. al-Qadisiyah Journal for Engineering Sciences،Vol. 12, no. 4, pp.225-231.
https://search.emarefa.net/detail/BIM-1039393

Modern Language Association (MLA)

Farhan, Khawlah A.& Shallal, Muhannad A.. Push-out tests for determining shear strength and stiffness of perfobond connector-experimental study. al-Qadisiyah Journal for Engineering Sciences Vol. 12, no. 4 (2019), pp.225-231.
https://search.emarefa.net/detail/BIM-1039393

American Medical Association (AMA)

Farhan, Khawlah A.& Shallal, Muhannad A.. Push-out tests for determining shear strength and stiffness of perfobond connector-experimental study. al-Qadisiyah Journal for Engineering Sciences. 2019. Vol. 12, no. 4, pp.225-231.
https://search.emarefa.net/detail/BIM-1039393

Data Type

Journal Articles

Language

English

Notes

-

Record ID

BIM-1039393