Measuring Visual Function Using the MultiQuity System: Comparison with an Established Device

Joint Authors

Nolan, John M.
Smolarek-Kasprzak, Patrycja
Dennison, Jessica
Akuffo, Kwadwo Owusu
Kuchling, Robert
Stack, Jim
O’Regan, Graham
Beatty, Stephen

Source

Journal of Ophthalmology

Issue

Vol. 2014, Issue 2014 (31 Dec. 2014), pp.1-7, 7 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2014-12-16

Country of Publication

Egypt

No. of Pages

7

Main Subjects

Medicine

Abstract EN

Purpose.

To compare measures of visual acuity (VA) and contrast sensitivity (CS) from the Thompson Xpert 2000 and MultiQuity (MiQ) devices.

Methods.

Corrected distance VA (CDVA) and CS were measured in the right eye of 73 subjects, on an established system (Thompson Xpert) and a novel system (MiQ 720).

Regression was used to convert MiQ scores into the Thompson scale.

Agreement between the converted MiQ and Thompson scores was investigated using standard agreement indices.

Test-retest variability for both devices was also investigated, for a separate sample of 24 subjects.

Results.

For CDVA, agreement was strong between the MiQ and Thomson devices (accuracy = 0.993, precision = 0.889, CCC = 0.883).

For CS, agreement was also strong (accuracy = 0.996, precision = 0.911, CCC = 0.907).

Agreement was unaffected by demographic variables or by presence/absence of ocular pathology.

Test-retest agreement indices for both devices were excellent: in the range 0.88–0.96 for CDVA and in the range 0.90–0.98 for CS.

Conclusion.

MiQ measurements exhibit strong agreement with corresponding Thomson measurements, and test-retest results are good for both devices.

Agreement between the two devices is unaffected by age or ocular pathology.

American Psychological Association (APA)

Smolarek-Kasprzak, Patrycja& Nolan, John M.& Beatty, Stephen& Dennison, Jessica& Akuffo, Kwadwo Owusu& Kuchling, Robert…[et al.]. 2014. Measuring Visual Function Using the MultiQuity System: Comparison with an Established Device. Journal of Ophthalmology،Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-1042421

Modern Language Association (MLA)

Smolarek-Kasprzak, Patrycja…[et al.]. Measuring Visual Function Using the MultiQuity System: Comparison with an Established Device. Journal of Ophthalmology No. 2014 (2014), pp.1-7.
https://search.emarefa.net/detail/BIM-1042421

American Medical Association (AMA)

Smolarek-Kasprzak, Patrycja& Nolan, John M.& Beatty, Stephen& Dennison, Jessica& Akuffo, Kwadwo Owusu& Kuchling, Robert…[et al.]. Measuring Visual Function Using the MultiQuity System: Comparison with an Established Device. Journal of Ophthalmology. 2014. Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-1042421

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1042421