Low Dose X-Ray Sources and High Quantum Efficiency Sensors: The Next Challenge in Dental Digital Imaging?

Joint Authors

Mistry, Arnav R.
Uzbelger Feldman, Daniel
Yang, Jie
Ryterski, Eric

Source

Radiology Research and Practice

Issue

Vol. 2014, Issue 2014 (31 Dec. 2014), pp.1-7, 7 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2014-12-09

Country of Publication

Egypt

No. of Pages

7

Main Subjects

Medicine

Abstract EN

Objective(s).

The major challenge encountered to decrease the milliamperes (mA) level in X-ray imaging systems is the quantum noise phenomena.

This investigation evaluated dose exposure and image resolution of a low dose X-ray imaging (LDXI) prototype comprising a low mA X-ray source and a novel microlens-based sensor relative to current imaging technologies.

Study Design.

A LDXI in static (group 1) and dynamic (group 2) modes was compared to medical fluoroscopy (group 3), digital intraoral radiography (group 4), and CBCT scan (group 5) using a dental phantom.

Results.

The Mann-Whitney test showed no statistical significance (α=0.01) in dose exposure between groups 1 and 3 and 1 and 4 and timing exposure (seconds) between groups 1 and 5 and 2 and 3.

Image resolution test showed group 1 > group 4 > group 2 > group 3 > group 5.

Conclusions.

The LDXI proved the concept for obtaining a high definition image resolution for static and dynamic radiography at lower or similar dose exposure and smaller pixel size, respectively, when compared to current imaging technologies.

Lower mA at the X-ray source and high QE at the detector level principles with microlens could be applied to current imaging technologies to considerably reduce dose exposure without compromising image resolution in the near future.

American Psychological Association (APA)

Mistry, Arnav R.& Uzbelger Feldman, Daniel& Yang, Jie& Ryterski, Eric. 2014. Low Dose X-Ray Sources and High Quantum Efficiency Sensors: The Next Challenge in Dental Digital Imaging?. Radiology Research and Practice،Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-1047428

Modern Language Association (MLA)

Mistry, Arnav R.…[et al.]. Low Dose X-Ray Sources and High Quantum Efficiency Sensors: The Next Challenge in Dental Digital Imaging?. Radiology Research and Practice No. 2014 (2014), pp.1-7.
https://search.emarefa.net/detail/BIM-1047428

American Medical Association (AMA)

Mistry, Arnav R.& Uzbelger Feldman, Daniel& Yang, Jie& Ryterski, Eric. Low Dose X-Ray Sources and High Quantum Efficiency Sensors: The Next Challenge in Dental Digital Imaging?. Radiology Research and Practice. 2014. Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-1047428

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1047428