Procedure of Active Residual Heat Removal after Emergency Shutdown of High-Temperature-Gas-Cooled Reactor

Joint Authors

Yang, Xingtuan
Sun, Yanfei
Ju, Huaiming
Jiang, Shengyao

Source

Science and Technology of Nuclear Installations

Issue

Vol. 2014, Issue 2014 (31 Dec. 2014), pp.1-10, 10 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2014-07-07

Country of Publication

Egypt

No. of Pages

10

Abstract EN

After emergency shutdown of high-temperature-gas-cooled reactor, the residual heat of the reactor core should be removed.

As the natural circulation process spends too long period of time to be utilized, an active residual heat removal procedure is needed, which makes use of steam generator and start-up loop.

During this procedure, the structure of steam generator may suffer cold/heat shock because of the sudden load of coolant or hot helium at the first few minutes.

Transient analysis was carried out based on a one-dimensional mathematical model for steam generator and steam pipe of start-up loop to achieve safety and reliability.

The results show that steam generator should be discharged and precooled; otherwise, boiling will arise and introduce a cold shock to the boiling tubes and tube sheet when coolant began to circulate prior to the helium.

Additionally, in avoiding heat shock caused by the sudden load of helium, the helium circulation should be restricted to start with an extreme low flow rate; meanwhile, the coolant of steam generator (water) should have flow rate as large as possible.

Finally, a four-step procedure with precooling process of steam generator was recommended; sensitive study for the main parameters was conducted.

American Psychological Association (APA)

Yang, Xingtuan& Sun, Yanfei& Ju, Huaiming& Jiang, Shengyao. 2014. Procedure of Active Residual Heat Removal after Emergency Shutdown of High-Temperature-Gas-Cooled Reactor. Science and Technology of Nuclear Installations،Vol. 2014, no. 2014, pp.1-10.
https://search.emarefa.net/detail/BIM-1047772

Modern Language Association (MLA)

Yang, Xingtuan…[et al.]. Procedure of Active Residual Heat Removal after Emergency Shutdown of High-Temperature-Gas-Cooled Reactor. Science and Technology of Nuclear Installations No. 2014 (2014), pp.1-10.
https://search.emarefa.net/detail/BIM-1047772

American Medical Association (AMA)

Yang, Xingtuan& Sun, Yanfei& Ju, Huaiming& Jiang, Shengyao. Procedure of Active Residual Heat Removal after Emergency Shutdown of High-Temperature-Gas-Cooled Reactor. Science and Technology of Nuclear Installations. 2014. Vol. 2014, no. 2014, pp.1-10.
https://search.emarefa.net/detail/BIM-1047772

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1047772