Validation of New and Existing Decision Rules for the Estimation of Beat-to-Beat Pulse Transit Time

Joint Authors

Zhou, Xiaolin
Peng, Rongchao
Ding, Hongxia
Zhang, Ningling
Li, Pan

Source

BioMed Research International

Issue

Vol. 2015, Issue 2015 (31 Dec. 2015), pp.1-13, 13 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2015-03-02

Country of Publication

Egypt

No. of Pages

13

Main Subjects

Medicine

Abstract EN

Pulse transit time (PTT) is a pivotal marker of vascular stiffness.

Because the actual PTT duration in vivo is unknown and the complicated variation in waveform may occur, the robust determination of characteristic point is still a very difficult task in the PTT estimation.

Our objective is to devise a method for real-time estimation of PTT duration in pulse wave.

It has an ability to reduce the interference caused by both high- and low-frequency noise.

The reproducibility and performance of these methods are assessed on both artificial and clinical pulse data.

Artificial data are generated to investigate the reproducibility with various signal-to-noise ratios.

For all artificial data, the mean biases obtained from all methods are less than 1 ms; collectively, this newly proposed method has minimum standard deviation (SD, <1 ms).

A set of data from 33 participants together with the synchronously recorded continuous blood pressure data are used to investigate the correlation coefficient (CC).

The statistical analysis shows that our method has maximum values of mean CC (0.5231), sum of CCs (17.26), and median CC (0.5695) and has the minimum SD of CCs (0.1943).

Overall, the test results in this study indicate that the newly developed method has advantages over traditional decision rules for the PTT measurement.

American Psychological Association (APA)

Zhou, Xiaolin& Peng, Rongchao& Ding, Hongxia& Zhang, Ningling& Li, Pan. 2015. Validation of New and Existing Decision Rules for the Estimation of Beat-to-Beat Pulse Transit Time. BioMed Research International،Vol. 2015, no. 2015, pp.1-13.
https://search.emarefa.net/detail/BIM-1054983

Modern Language Association (MLA)

Zhou, Xiaolin…[et al.]. Validation of New and Existing Decision Rules for the Estimation of Beat-to-Beat Pulse Transit Time. BioMed Research International No. 2015 (2015), pp.1-13.
https://search.emarefa.net/detail/BIM-1054983

American Medical Association (AMA)

Zhou, Xiaolin& Peng, Rongchao& Ding, Hongxia& Zhang, Ningling& Li, Pan. Validation of New and Existing Decision Rules for the Estimation of Beat-to-Beat Pulse Transit Time. BioMed Research International. 2015. Vol. 2015, no. 2015, pp.1-13.
https://search.emarefa.net/detail/BIM-1054983

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1054983